Ara
Toplam kayıt 8, listelenen: 1-8
Minimally redundant 2-D array designs for 3-D medical ultrasound imaging
(IEEE-Inst Electrical Electronics Engineers Inc, 2009-07)
In real-time ultrasonic 3-D imaging, in addition to difficulties in fabricating and interconnecting 2-D transducer arrays with hundreds of elements, there are also challenges in acquiring and processing data from a large ...
Coherent array imaging using phased subarrays. Part II: Simulations and experimental results
(IEEE-INST Electrical Electronics Engineers Inc, 2005-01)
The basic principles and theory of phased subarray (PSA) imaging imaging provides the flexibility of reducing I he number of front-end hardware channels between that of classical synthetic aperture (CSA) imaging-which uses ...
Dual-annular-ring CMUT array for forward-looking IVUS imaging
(IEEE, 2006)
We investigate a dual-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. The array consists of separate, concentric transmit and receive ring arrays built on the same ...
Volumetric imaging using fan-beam scanning with reduced redundancy 2D arrays
(IEEE, 2006)
Phased array processing with a fully populated 2D array produces the best image quality but requires excessive number of active parallel front-end channels. Here we explore four array designs with reduced redundancy in ...
Evaluation of CMUT annular arrays for side-looking IVUS
(IEEE, 2009)
Side-looking (SL) IVUS probes are extensively used for management of cardiovascular diseases. Currently SL-IVUS imaging probes use either a single rotating transducer element or solid-state arrays. Probes with single ...
Phased subarray imaging for low-cost, wideband coherent array imaging
(IEEE, 2003)
The front-end hardware complexity of conventional full phased array (FPA) imaging is proportional to the number of array elements. Phased subarray (PSA) imaging has been proposed as a method of reducing the hardware ...
Volumetric imaging using 2D capacitive micromachined ultrasonic transducer arrays (CMUTs): Initial results
(IEEE, 2002)
This paper presents the first volumetric images obtained using a 2D CMUT array with through-wafer via interconnects. An 8×16-element portion of a 32×64-element array flip-chip bonded onto a glass fanout chip was used in ...
Subarray delta-sigma beamforming for ultrasonic imaging
(IEEE, 2002)
We present a beamforming architecture based on subarray processing with non-uniform oversampling 1-bit delta-sigma (??) modulation. The subarray processing combines conventional phased array and synthetic aperture approaches ...