Ara
Toplam kayıt 15, listelenen: 1-10
Damariçi yanal kesit görüntüleme için farklı prob yapılarının incelenmesi
(IEEE, 2009-06-26)
Bu çalışmada dönen bir şaftın yanal yüzeyine yerleştirilmiş 8 adet içiçe halka elemanlardan oluşan yana bakan görüntüleme için yeni bir kateter yapısı incelenmiştir. Bu Katater mimarisi basit bir dizi önü alıcı verici ...
Status of the Focal Plane Instrumentation (FPI) Project of the 4 m DAG Telescope
(SPIE, 2016-08-09)
DAG (Eastern Anatolia Observatory in Turkish) will be the newest and largest (4m) observatory of Turkey in both optical (VIS) and near-infrared (NIR) Owith its robust observing site infrastructure. The telescope is designedOto ...
An adaptive locally connected neuron model: Focusing neuron
(Elsevier B.V., 2021-01-02)
This paper presents a new artificial neuron model capable of learning its receptive field in the topological domain of inputs. The experiments include tests of focusing neuron networks of one or two hidden layers on synthetic ...
Annular CMUT arrays for side looking intravascular ultrasound imaging
(IEEE, 2007)
Although side looking intravascular ultrasound (SL-IVUS) imaging systems using single element piezoelectric transducers set the resolution standard in the assessment of the extent of coronary artery disease, improvements ...
An integrated circuit with transmit beamforming and parallel receive channels for real-time three-dimensional ultrasound imaging
(IEEE, 2006)
We present the design of an integrated circuit (IC) that will be flip-chip bonded to a 16 x 16-element CMUT array. The IC provides 16 receive channels which can be configured to receive along either of the array diagonals ...
A tunable analog delay element for high-frequency dynamic beamforming
(IEEE, 2009)
Implementing beamforming for high frequency arrays is challenging because of the accurate delay requirements at high frequencies. High frequency digital beamforming is not suitable for catheter based applications as a large ...
Evaluation of CMUT annular arrays for side-looking IVUS
(IEEE, 2009)
Side-looking (SL) IVUS probes are extensively used for management of cardiovascular diseases. Currently SL-IVUS imaging probes use either a single rotating transducer element or solid-state arrays. Probes with single ...
Real-time range sensing with a Scheimpflug camera and a single custom sensor/processor chip
(SPIE-Int Soc Optical Engineering, 2003)
An image-based range sensing technique is presented. The technique is originally considered for highway collision avoidance applications but its generality makes it suitable for application in robotics, manufacturing and ...
Subarray delta-sigma beamforming for ultrasonic imaging
(IEEE, 2002)
We present a beamforming architecture based on subarray processing with non-uniform oversampling 1-bit delta-sigma (??) modulation. The subarray processing combines conventional phased array and synthetic aperture approaches ...
Uyarlanır yerel bağlı katman kullanan dikkat tabanlı derin ağ ile sesli komut tanıma
(Institute of Electrical and Electronics Engineers Inc., 2020-10-05)
Sesli komut tanıma insan-makine ara yüzüyle ilişkili aktif bir araştırma konusudur. Dikkat tabanlı derin ağlar ile bu tür problemler başarılı bir şekilde çözülebilmektedir. Bu çalışmada, var olan bir dikkat tabanlı derin ...