dc.identifier.citationKitis, G., Polymeris, G. S., Güneç Kıyak, N., & Pagonis, V. (2011). Preliminary results towards the equivalence of transformed continuous-wave optically stimulated luminescence (CW-OSL) and linearly-modulated (LM-OSL) signals in quartz. Geochronometria, 38(3), 209-216. doi:10.2478/s13386-011-0031-8en_US
dc.identifier.issn1733-8387en_US
dc.identifier.urihttps://hdl.handle.net/11729/411
dc.identifier.urihttp://dx.doi.org/10.2478/s13386-011-0031-8
dc.description.abstractThe present paper presents a comparative experimental study of two commonly measured Optically Stimulated Luminescence (OSL) signals in quartz. The experimental study measures both the continuous wave OSL (CW-OSL) and the linearly modulated (LM-OSL) signals from the same quartz sample for a range of stimulation temperatures between 180 and 280A degrees C, while the former is transformed to pseudo LM-OSL (ps LM-OSL). A computerized deconvolution curve analysis of the LM-OSL and ps LM-OSL signals was carried out, and the contributions of several OSL components to the initial OSL signal (0.1 s) were shown to be independent of the stimulation temperature used during the measurement. It was also found that the composite OSL (0.1 s) signal consists mainly of the first two OSL components present in the OSL curves. The equivalence of the ps LM-OSL (transformed CW-OSL) and of LM-OSL measurements was also examined by an appropriate choice of the experimental stimulation times, and of the stimulation power of the blue LEDs used during the measurement.en_US
dc.description.sponsorshipGeorge S. Polymeris is financially supported by TUBITAK (The Scientific and Technological Research Council of Turkey), in the framework of a Post-doc Fellowship for foreign citizensen_US
dc.language.isoenen_US
dc.publisherVersitaen_US
dc.relation.ispartofGeochronometriaen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectGeologyen_US
dc.subjectPaleontologyen_US
dc.subjectOSLen_US
dc.subjectTransformed CW-OSLen_US
dc.subjectLM-OSLen_US
dc.subjectPseudo LM-OSLen_US
dc.subjectQuartz datingen_US
dc.subjectOSL componentsen_US
dc.subjectComputerized OSL analysisen_US
dc.subjectComponenten_US
dc.subjectSamplesen_US
dc.subjectRelevanceen_US
dc.subjectCurvesen_US
dc.subjectDecayen_US
dc.subjectTlen_US
dc.titlePreliminary results towards the equivalence of transformed continuous-wave Optically Stimulated Luminescence (CW-OSL) and linearly-modulated (LM-OSL) signals in quartzen_US
dc.typeArticleen_US
dc.description.versionPublisher's Versionen_US
dc.departmentIşık Üniversitesi, Fen Edebiyat Fakültesi, Fizik Bölümüen_US
dc.departmentIşık University, Faculty of Arts and Sciences, Department of Physicsen_US
dc.authorid0000-0002-9972-429X
dc.authorid0000-0002-9972-429Xen_US
dc.identifier.volume38
dc.identifier.issue3
dc.identifier.issueSI
dc.identifier.startpage209
dc.identifier.endpage216
dc.peerreviewedYesen_US
dc.publicationstatusPublisheden_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.institutionauthorPolymeris, George S.en_US
dc.institutionauthorGüneç Kıyak, Nafiyeen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakScience Citation Index Expanded (SCI-EXPANDED)en_US
dc.identifier.wosqualityQ4
dc.identifier.wosqualityQ4en_US
dc.identifier.wosWOS:000291941300004
dc.identifier.wosWOS:000291941300004en_US
dc.identifier.scopus2-s2.0-80155211700en_US
dc.identifier.doi10.2478/s13386-011-0031-8
dc.identifier.scopusqualityQ2en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster