Ara
Toplam kayıt 35, listelenen: 11-20
Tıbbi ultrasonik kanal içi görüntüleme için yeni yöntemler
(Tübitak, 2008-09)
Yakın zamanda yapılan çalışmalarımızdaki yaklaşımda, aktif kanal sayısını azaltmak için fazlalık (redundant) gönderme-alma eleman ikilileri azalırken gerekli olan (non-redundant) gönderme-alma eleman ikilileri korunmaktadır. ...
Evaluation of CMUT annular arrays for side-looking IVUS
(IEEE, 2009)
Side-looking (SL) IVUS probes are extensively used for management of cardiovascular diseases. Currently SL-IVUS imaging probes use either a single rotating transducer element or solid-state arrays. Probes with single ...
A tunable analog delay element for high-frequency dynamic beamforming
(IEEE, 2009)
Implementing beamforming for high frequency arrays is challenging because of the accurate delay requirements at high frequencies. High frequency digital beamforming is not suitable for catheter based applications as a large ...
Front-end CMOS electronics for monolithic integration with CMUT arrays: Circuit design and initial experimental results
(2008)
This paper discusses design of CMOS-ASICs for monolithic integration of CMUT arrays by post-CMOS fabrication. We describe design strategies for monolithic integration and demonstrate the advantages of CMUT-on-CMOS approach. ...
Co-array optimization of CMUT arrays for forward-looking IVUS
(IEEE, 2009-09)
The ring annular array structure is a preferred configuration for implementing Forward-Looking IVUS (FLIVUS) catheters as it allows for volumetric imaging as well as use of a guidewire at the center. CMUT technology is ...
An endoscopie imaging system based on a two-dimensional CMUT array: real-time imaging results
(IEEE, 2005)
Real-time catheter-based ultrasound imaging tools are needed for diagnosis and image-guided procedures. The continued development of these tools is partially limited by the difficulty of fabricating two-dimensional array ...
Micromachined capacitive transducer arrays for intravascular ultrasound
(SPIE, 2005)
Intravascular ultrasound (IVUS) imaging has become an essential imaging modality for the effective diagnosis and treatment of cardiovascular diseases during the past decade enabled by innovative applications of piezoelectric ...
Dual-annular-ring CMUT array for forward-looking IVUS imaging
(IEEE, 2006)
We investigate a dual-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. The array consists of separate, concentric transmit and receive ring arrays built on the same ...
An integrated circuit with transmit beamforming and parallel receive channels for real-time three-dimensional ultrasound imaging
(IEEE, 2006)
We present the design of an integrated circuit (IC) that will be flip-chip bonded to a 16 x 16-element CMUT array. The IC provides 16 receive channels which can be configured to receive along either of the array diagonals ...
Beamforming and hardware design for a multichannel front-end integrated circuit for real-time 3D catheter-based ultrasonic imaging
(SPIE-Int Soc Optical Engineering, 2006)
We are working on integrating front-end electronics with the ultrasound transducer array for real-time 3D ultrasound imaging systems. We achieve this integration by flip-chip bonding a two-dimensional transducer array to ...