Demirci, U., Ergün, A. S., Oralkan, Ö. & Khuri-Yakub, B. T. (2004). Forward-viewing CMUT arrays for medical imaging. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 49; 51(7), 887-895. doi:10.1109/TUFFC.2004.1320749Özet
This paper reports the design and testing of forward-viewing annular arrays fabricated using capacitive micromachined ultrasonic transducer (CMUT) technology. Recent research studies have shown that CMUTs have broad frequency bandwidth and high-transduction efficiency. One- and two-dimensional CMUT arrays of various sizes already have been fabricated, and their viability for medical imaging applications has been demonstrated. We fabricated 64-element, forward-viewing annular arrays using the standard CMUT fabrication process and carried out experiments to measure the operating frequency, bandwidth, and transmit/receive efficiency of the array elements. The annular array elements, designed for imaging applications in the 20 MHz range, had a resonance frequency of 13.5 MHz in air. The immersion pulse-echo data collected from a plane reflector showed that the devices operate in the 5-26 MHz range with a fractional bandwidth of 135%. The output pressure at the surface of the transducer was measured to be 24 kPa/V. These values translate into a dynamic range of 131.5 dB for I-V excitation in 1-Hz bandwidth with a commercial low noise receiving circuitry. The designed, forward-viewing annular CMUT array is suitable for mounting on the front surface of a cylindrical catheter probe and can provide Doppler information for measurement of blood flow and guiding information for navigation through blood vessels in intravascular ultrasound imaging.
Kaynak
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency ControlCilt
51Sayı
7İlgili Öğeler
Başlık, yazar, küratör ve konuya göre gösterilen ilgili öğeler.
-
An integrated circuit with transmit beamforming and parallel receive channels for 3D ultrasound imaging: testing and characterization
Wygant, Ira O.; Jamal, Nafis S.; Lee, Hyunjoo J.; Nikoozadeh, Amin; Zhuang, Xuefeng; Oralkan, Ömer; Ergün, Arif Sanlı; Karaman, Mustafa; Khuri-Yakub, Butrus Thomas (IEEE, 2007)The cost and complexity of medical ultrasound imaging systems can be reduced by integrating the transducer array with an integrated circuit (IC). By incorporating some of the system's front-end electronics into an IC, bulky ... -
Annular CMUT arrays for side looking intravascular ultrasound imaging
Zahorian, Jaime; Güldiken, Rasim Oytun; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Carlier, Stephane; Şişman, Alper; Karaman, Mustafa (IEEE, 2007)Although side looking intravascular ultrasound (SL-IVUS) imaging systems using single element piezoelectric transducers set the resolution standard in the assessment of the extent of coronary artery disease, improvements ... -
Üç boyutlu akustik görüntüleme için ön alıcı-verici tümdevre
Çiçek, İhsan; Bozkurt, Ayhan; Karaman, Mustafa (IEEE, 2004)Tıbbi ultrasonik görüntüleme sistemleri, genel olarak bir çevirici elemanı ve akustik işaretin üretilip algılanmasından sorumlu elektronik oluşmaktadır. Tek boyutlu dönüştürücü dizileriyle, incelenmekte olan ortamın iki ...