Basit öğe kaydını göster

dc.contributor.authorTekeş, Coşkunen_US
dc.contributor.authorKaraman, Mustafaen_US
dc.contributor.authorDeğertekin, Fahrettin Leventen_US
dc.date.accessioned2015-01-15T23:01:50Z
dc.date.available2015-01-15T23:01:50Z
dc.date.issued2011-12
dc.identifier.citationTekeş, C., Karaman, M. & Değertekin, F. L. (2011). Optimizing circular ring arrays for forward- looking IVUS imaging. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 58(12), 2596-2607. doi:10.1109/TUFFC.2011.2123en_US
dc.identifier.issn0885-3010
dc.identifier.issn1525-8955
dc.identifier.urihttps://hdl.handle.net/11729/393
dc.identifier.urihttp://dx.doi.org/10.1109/TUFFC.2011.2123
dc.description.abstractForward-looking (FL) catheter-based imaging systems are highly desirable for guiding interventions in intravascular ultrasound (IVUS) applications. One of the main challenges of array-based FL-IVUS systems is the large channel count, which results in increased system complexity. Synthetic phased-array processing with a reduced firing count simplifies the front-end and, hence, can enable 3-D real-time imaging. Recently, we have investigated dual-ring arrays suitable for IVUS imaging, in which the two concentric circular arrays are used separately as transmit (Tx) and receive (Rx) arrays. In this study, we present different optimized array designs based on dual and single circular rings which are suitable for synthetic phased-array processing with a reduced number of firings. To obtain an optimal firing set that produces low side lobes in the wideband response, we use a simulated annealing algorithm. In the simulations, we use 1.2-mm-diameter array configurations with 64 Tx and 58 Rx elements, a center frequency of 20 MHz and fractional bandwidths of 50% and 80%. The results show that optimized dual-ring arrays provide 8 dB improvements in peak near side-lobe level with no widening in the main lobe width when compared with full and other sparse co-arrays.en_US
dc.language.isoengen_US
dc.publisherIEEE-Inst Electrical Electronics Engineers Incen_US
dc.relation.isversionof10.1109/TUFFC.2011.2123
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectMicromachined ultrasonic transducersen_US
dc.subjectIntravascular ultrasounden_US
dc.subjectRadiation-patternen_US
dc.subjectArbitrary Shapeen_US
dc.subjectPhased subarmysen_US
dc.subjectCmut arraysen_US
dc.subjectPart iien_US
dc.subjectCatheteren_US
dc.subjectApertureen_US
dc.subjectFabricationen_US
dc.titleOptimizing circular ring arrays for forward-looking IVUS imagingen_US
dc.typearticleen_US
dc.description.versionPublisher's Versionen_US
dc.relation.journalIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Controlen_US
dc.contributor.departmentIşık Üniversitesi, Mühendislik Fakültesi, Elektrik-Elektronik Mühendisliği Bölümüen_US
dc.contributor.departmentIşık University, Faculty of Engineering, Department of Electrical-Electronics Engineeringen_US
dc.contributor.authorID0000-0002-2357-4424
dc.identifier.volume58
dc.identifier.issue12
dc.identifier.startpage2596
dc.identifier.endpage2607
dc.peerreviewedYesen_US
dc.publicationstatusPublisheden_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorTekeş, Coşkunen_US
dc.contributor.institutionauthorKaraman, Mustafaen_US
dc.relation.indexWOSen_US
dc.relation.indexScopusen_US
dc.relation.indexPubMeden_US
dc.relation.indexScience Citation Index Expanded (SCI-EXPANDED)en_US
dc.description.qualityQ1
dc.description.wosidWOS:000300092800012
dc.description.pubmedidPMID:23443696


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster