Basit öğe kaydını göster

dc.contributor.authorPolymeris, George S.en_US
dc.contributor.authorOniya, Ebenezer O.en_US
dc.contributor.authorJibiri, Nnamdi N.en_US
dc.contributor.authorTsirliganis, Nestor C.en_US
dc.contributor.authorKitis, Georgeen_US
dc.date.accessioned2015-01-15T23:02:04Z
dc.date.available2015-01-15T23:02:04Z
dc.date.issued2012-03-01
dc.identifier.citationPolymeris, G., Oniya, E., Jibiri, N., Tsirliganis, N., & Kitis, G. (2012). In-homogeneity in the pre-dose sensitization of the 110 degrees C TL peak in various quartz samples: The influence of annealing. Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 274, 105-110. doi:10.1016/j.nimb.2011.12.001en_US
dc.identifier.issn0168-583X
dc.identifier.urihttps://hdl.handle.net/11729/453
dc.identifier.urihttp://dx.doi.org/10.1016/j.nimb.2011.12.001
dc.description.abstractThe pre-dose sensitization effect of the 110 degrees C TL glow-peak of quartz is a basic tool in thermoluminescence and optically stimulated luminescence dating and retrospective dosimetry. In the present work, a homogeneity study was performed on pre-dose sensitization in grains obtained from large quartz crystals samples collected from 10 different origins. The aliquot - to - aliquot scatter of the pre-dose sensitization of the 110 degrees C TL peak within each quartz crystal was monitored. The influence of the annealing on this scattering was also studied. Therefore, the investigation was applied to the un-fired "as is" samples as well as to samples annealed at 900 degrees C for 1 h following cooling to room temperature in air. The results showed that in the case of "as is" quartz the sensitization effect vary strongly within each aliquot of the same quartz sample. This strong variation is removed by both the high temperature annealing as well as heating up to 500 degrees C, involved in the TL measurements. These results are generally discussed in the framework of existing models and applications of the effect.en_US
dc.language.isoengen_US
dc.publisherElsevier Science BVen_US
dc.relation.isversionof10.1016/j.nimb.2011.12.001
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPhysicsen_US
dc.subjectQuartzen_US
dc.subjectThermoluminescence (TL)en_US
dc.subject110 degrees C TL glow-peaken_US
dc.subjectPre-dose effecten_US
dc.subjectSensitizationen_US
dc.subjectAliquot - to - aliquot scatteren_US
dc.subjectLuminescence sensitivity changesen_US
dc.subjectOptically stimulated luminescenceen_US
dc.subjectElectron-Spin-Resonanceen_US
dc.subjectSynthetic quartzen_US
dc.subjectThermo-Luminescenceen_US
dc.subjectSedimentary quartzen_US
dc.subjectFiring temperatureen_US
dc.subjectThermoluminescenceen_US
dc.subjectOSLen_US
dc.subjectSuperlinearityen_US
dc.titleIn-homogeneity in the pre-dose sensitization of the 110 degrees C TL peak in various quartz samples: The influence of annealingen_US
dc.typearticleen_US
dc.description.versionPublisher's Versionen_US
dc.relation.journalNuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atomsen_US
dc.contributor.departmentIşık Üniversitesi, Fen Edebiyat Fakültesi, Fizik Bölümüen_US
dc.contributor.departmentIşık University, Faculty of Arts and Sciences, Department of Physicsen_US
dc.contributor.authorID0000-0002-9972-429X
dc.identifier.volume274
dc.identifier.startpage105
dc.identifier.endpage110
dc.peerreviewedYesen_US
dc.publicationstatusPublisheden_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorPolymeris, George S.en_US
dc.relation.indexWOSen_US
dc.relation.indexScopusen_US
dc.relation.indexScience Citation Index Expanded (SCI-EXPANDED)en_US
dc.description.qualityQ3
dc.description.wosidWOS:000301611900014


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster