Basit öğe kaydını göster

dc.contributor.authorGüneç Kıyak, Nafiyeen_US
dc.contributor.authorKitis, Georgeen_US
dc.contributor.authorPolymeris, George S.en_US
dc.date.accessioned2015-11-06T08:03:41Z
dc.date.available2015-11-06T08:03:41Z
dc.date.issued2015-09-15
dc.identifier.citationKitis, G., Güneç Kıyak, N. & Polymeris, G. S. (2015). Temperature lags of luminescence measurements in a commercial luminescence reader. Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 359, 60-63. doi:10.1016/j.nimb.2015.07.041en_US
dc.identifier.issn0168-583X
dc.identifier.issn1872-9584
dc.identifier.urihttps://hdl.handle.net/11729/700
dc.identifier.urihttp://dx.doi.org/10.1016/j.nimb.2015.07.041
dc.description.abstractThe temperature recorded in thermoluminescence and optically stimulated luminescence equipments is not the temperature of the sample but that of the heating element on which the thermocouple is attached. Depending upon the rate of heating, a temperature difference appears between the samples and the heating element, termed as temperature lag, which could have serious effects on the curve shapes and trapping parameters. In the present work the temperature lag effect is studied in a newly developed luminescence equipment measuring both thermoluminescence and optically stimulated luminescence. It is found that the temperature lag could be large for heating rates above 2 K/s and it is strongly dependent upon the sample holder. A simple approximation method is proposed in order to both predict as well as correct for temperature lag effects in luminescence measurements.en_US
dc.language.isoengen_US
dc.publisherElsevier Science Incen_US
dc.relation.isversionof10.1016/j.nimb.2015.07.041
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectTemperature lagen_US
dc.subjectTLD 100en_US
dc.subjectLuminescence readeren_US
dc.subjectDe-convolutionen_US
dc.subjectAnalysis computer-programsen_US
dc.subjectNonideal heat-transferen_US
dc.subjectGlow-curveen_US
dc.subjectThermoluminescence experimentsen_US
dc.subjectParametersen_US
dc.subjectKineticsen_US
dc.titleTemperature lags of luminescence measurements in a commercial luminescence readeren_US
dc.typearticleen_US
dc.description.versionPublisher's Versionen_US
dc.relation.journalNuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atomsen_US
dc.contributor.departmentIşık Üniversitesi, Fen Edebiyat Fakültesi, Fizik Bölümüen_US
dc.contributor.departmentIşık University, Faculty of Arts and Sciences, Department of Physicsen_US
dc.identifier.volume359
dc.identifier.startpage60
dc.identifier.endpage63
dc.peerreviewedYesen_US
dc.publicationstatusPublisheden_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorGüneç Kıyak, Nafiyeen_US
dc.relation.indexWOSen_US
dc.relation.indexScopusen_US
dc.relation.indexScience Citation Index Expanded (SCI-EXPANDED)en_US
dc.description.qualityQ3
dc.description.wosidWOS:000360868900009


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster