Basit öğe kaydını göster

dc.contributor.authorPolymeris, George S.en_US
dc.contributor.authorGoudouri, Ourania Mentien_US
dc.contributor.authorParaskevopoulos, Konstantinos M.en_US
dc.contributor.authorKitis, Georgeen_US
dc.date.accessioned2015-12-10T07:57:31Z
dc.date.available2015-12-10T07:57:31Z
dc.date.issued2011-11-06
dc.identifier.citationPolymeris, G. S., Goudouri, O. M., Paraskevopoulos, K. M., & Kitis, G. (2012). The 110°C thermoluminescence peak as a probe in bioactivity study of the 58S sol-gel bioactive glass. Paper presented at the , 493-494 49-54. doi:10.4028/www.scientific.net/KEM.493-494.49en_US
dc.identifier.isbn9783037852552
dc.identifier.issn1013-9826
dc.identifier.urihttps://hdl.handle.net/11729/741
dc.identifier.urihttp://dx.doi.org/10.4028/www.scientific.net/KEM.493-494.49
dc.description.abstractResults of the present study provide strong indications towards the effective application of the 110°C Thermoluminescence (TL) peak in discriminating between different bioactive responses for the case of the 58S bioactive glass. The in vitro bioactivity of this glass in the form of powder in SBF solution was tested for various immersion times, ranging between 0 and 6 days. This TL peak is ubiquitously present in all 58S samples, for all immersion times. The intensity of the 110°C TL peak was proven to be very sensitive to the different bioactive responses, indicating a strongly decreasing pattern with increasing immersion time in SBF, easily identifying thus the loss of silica. This loss is reflected to the decrease of the 110°C TL peak intensity, which appears to be fast even for the shorter immersion times. The 110°C TL glow peak intensity and sensitization could also be yielding a time scale regarding the beginning of some among the several stages included in the bioactivity sequence.en_US
dc.language.isoengen_US
dc.publisherTrans Tech Publications Ltden_US
dc.relation.isversionof10.4028/www.scientific.net/KEM.493-494.49
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBioactive responseen_US
dc.subjectSBFen_US
dc.subjectSensitivityen_US
dc.subjectSensitizationen_US
dc.subject58S bioactive glassen_US
dc.subjectGlow peaksen_US
dc.subjectImmersion timeen_US
dc.subjectIn-vitro bioactivityen_US
dc.subjectPeak intensityen_US
dc.subjectSBF solutionen_US
dc.subjectThermoluminescence peaksen_US
dc.subjectTime-scalesen_US
dc.subjectBioactivityen_US
dc.subjectBioceramicsen_US
dc.subjectSilicaen_US
dc.subjectThermoluminescenceen_US
dc.subjectBioactive glassen_US
dc.titleThe 110°C Thermoluminescence peak as a probe in bioactivity study of the 58S sol-gel bioactive glassen_US
dc.typeconferenceObjecten_US
dc.description.versionPublisher's Versionen_US
dc.relation.journalKey Engineering Materialsen_US
dc.contributor.departmentIşık Üniversitesi, Fen Edebiyat Fakültesi, Fizik Bölümüen_US
dc.contributor.departmentIşık University, Faculty of Arts and Sciences, Department of Physicsen_US
dc.contributor.authorID0000-0002-9972-429X
dc.identifier.volume493-494
dc.identifier.startpage49
dc.identifier.endpage54
dc.peerreviewedYesen_US
dc.publicationstatusPublisheden_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorPolymeris, George S.en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster