Annular CMUT arrays for side looking intravascular ultrasound imaging
(IEEE, 2007)
Although side looking intravascular ultrasound (SL-IVUS) imaging systems using single element piezoelectric transducers set the resolution standard in the assessment of the extent of coronary artery disease, improvements ...
Forward-looking IVUS imaging using a dual-annular ring CMUT array: Experimental results
(IEEE, 2007)
This paper presents the experimental results on forward-looking Intravascular ultrasound (FL-IVUS) using dual-annular-ring CMUT arrays. The array has a diameter of 1mm including bondpads which consists of separate, concentric ...
Dual-annular-ring CMUT array for forward-looking IVUS imaging
(IEEE, 2006)
We investigate a dual-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. The array consists of separate, concentric transmit and receive ring arrays built on the same ...
Front-end CMOS electronics for monolithic integration with CMUT arrays: Circuit design and initial experimental results
(2008)
This paper discusses design of CMOS-ASICs for monolithic integration of CMUT arrays by post-CMOS fabrication. We describe design strategies for monolithic integration and demonstrate the advantages of CMUT-on-CMOS approach. ...
Multiple annular ring capacitive micromachined ultrasonic transducer arrays for forward-looking intravascular ultrasound imaging catheters
(American Society of Mechanical Engineers (ASME), 2007)
We investigate multiple-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. This configuration has the potential for independent optimization of each ring and uses the ...
A tunable analog delay element for high-frequency dynamic beamforming
(IEEE, 2009)
Implementing beamforming for high frequency arrays is challenging because of the accurate delay requirements at high frequencies. High frequency digital beamforming is not suitable for catheter based applications as a large ...
Evaluation of CMUT annular arrays for side-looking IVUS
(IEEE, 2009)
Side-looking (SL) IVUS probes are extensively used for management of cardiovascular diseases. Currently SL-IVUS imaging probes use either a single rotating transducer element or solid-state arrays. Probes with single ...
Forward-looking IVUS imaging using an annular-ring CMUT array
(IEEE, 2005)
A 64-element, 1.15mm diameter annular-ring CMUT array was characterized and used for forward-looking IVUS imaging tests. The array was manufactured using low temperature processes suitable for CMOS electronics integration ...
Dual electrode capacitive micromachined ultrasonic transducer array for 1-D intracardiac echocardiography (ICE)
(American Society of Mechanical Engineers (ASME), 2007)
We designed and fabricated a 64 element 1-D linear dual electrode Capacitive Micromachined Ultrasonic Transducer (CMUT) array operating at 9.5 MHz for Intracardiac Echocardiography (ICE). The dual electrode CMUT structure ...
Micromachined capacitive transducer arrays for intravascular ultrasound
(SPIE, 2005)