An integrated circuit with transmit beamforming and parallel receive channels for 3D ultrasound imaging: testing and characterization

View/ Open
Date
2007Author
Wygant, Ira O.Jamal, Nafis S.
Lee, Hyunjoo J.
Nikoozadeh, Amin
Zhuang, Xuefeng
Oralkan, Ömer
Ergün, Arif Sanlı
Karaman, Mustafa
Khuri-Yakub, Butrus Thomas
Metadata
Show full item recordCitation
Wygant, I. O., Jamal, N. S., Lee, H. J., Nikoozadeh, A., Zhuang, X., Oralkan, Ö., . . . Khuri-Yakub, B. T. (2007). An integrated circuit with transmit beamforming and parallel receive channels for 3D ultrasound imaging: Testing and characterization. Paper presented at the 25-28. doi:10.1109/ULTSYM.2007.20Abstract
The cost and complexity of medical ultrasound imaging systems can be reduced by integrating the transducer array with an integrated circuit (IC). By incorporating some of the system's front-end electronics into an IC, bulky cables and costly system electronics can be eliminated. Here we present an IC for 3D intracavital imaging that requires few electrical connections but uses a large fraction of a 16x16-element 2D transducer array to transmit focused ultrasound. To simplify the receive and data acquisition electronics, only the 32 elements along the array diagonals are used as receivers. The IC provides a preamplifier for each receiving element. Each of the 224 transmitting elements is provided an 8-bit shift register, a comparator, and a 25-V pulser. To transmit, a global counter is incremented from 1 to 224; each pulser fires when its stored register value is equal to the global count value. Electrical testing of the fabricated IC shows that it works as designed. The IC was flip-chip bonded to a two-dimensional capacitive micromachined ultrasonic transducer (CMUT) array. A two-dimensional image of a wire target phantom was acquired.
Source
2007 IEEE Ultrasonics Symposium Proceedings, Vols 1-6Related items
Showing items related by title, author, creator and subject.
-
Annular CMUT arrays for side looking intravascular ultrasound imaging
Zahorian, Jaime; Güldiken, Rasim Oytun; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Carlier, Stephane; Şişman, Alper; Karaman, Mustafa (IEEE, 2007)Although side looking intravascular ultrasound (SL-IVUS) imaging systems using single element piezoelectric transducers set the resolution standard in the assessment of the extent of coronary artery disease, improvements ... -
Forward-looking IVUS imaging using a dual-annular ring CMUT array: Experimental results
Güldiken, Rasim Oytun; Zahorian, Jaime S.; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Tekeş, Coşkun; Hasler, Paul E.; Karaman, Mustafa; Carlier, Stephane; Değertekin, Fahrettin Levent (IEEE, 2007)This paper presents the experimental results on forward-looking Intravascular ultrasound (FL-IVUS) using dual-annular-ring CMUT arrays. The array has a diameter of 1mm including bondpads which consists of separate, concentric ... -
Evaluation of CMUT annular arrays for side-looking IVUS
Şişman, Alper; Zahorian, Jaime S.; Gürün, Gökçe; Karaman, Mustafa; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Hasler, Paul E. (IEEE, 2009)Side-looking (SL) IVUS probes are extensively used for management of cardiovascular diseases. Currently SL-IVUS imaging probes use either a single rotating transducer element or solid-state arrays. Probes with single ...