Basit öğe kaydını göster

dc.contributor.authorGüldiken, Rasim Oytunen_US
dc.contributor.authorZahorian, Jaime S.en_US
dc.contributor.authorGürün, Gökçeen_US
dc.contributor.authorQureshi, Muhammad Shakeelen_US
dc.contributor.authorBalantekin, Müjdaten_US
dc.contributor.authorTekeş, Coşkunen_US
dc.contributor.authorHasler, Paul E.en_US
dc.contributor.authorKaraman, Mustafaen_US
dc.contributor.authorCarlier, Stephaneen_US
dc.contributor.authorDeğertekin, Fahrettin Leventen_US
dc.date.accessioned2019-08-31T12:10:23Z
dc.date.accessioned2019-08-05T16:03:06Z
dc.date.available2019-08-31T12:10:23Z
dc.date.available2019-08-05T16:03:06Z
dc.date.issued2007
dc.identifier.citationGüldiken, R., Zahorian, J., Gürün, G., Qureshi, M. S., Balantekin, M., Tekeş, C., . . . Değertekin, F. L. (2007). Forward-looking IVUS imaging using a dual-annular ring CMUT array: Experimental results. Paper presented at the 2007 IEEE Ultrasonics Symposium Proceedings, 1247-1250. doi:10.1109/ULTSYM.2007.313en_US
dc.identifier.isbn9781424413836
dc.identifier.isbn1424413834
dc.identifier.isbn9781424413843
dc.identifier.issn1051-0117
dc.identifier.urihttps://hdl.handle.net/11729/1811
dc.identifier.urihttps://dx.doi.org/10.1109/ULTSYM.2007.313
dc.description.abstractThis paper presents the experimental results on forward-looking Intravascular ultrasound (FL-IVUS) using dual-annular-ring CMUT arrays. The array has a diameter of 1mm including bondpads which consists of separate, concentric 24 transmit and 32 receive ring arrays built on the same silicon substrate. This configuration has the potential for Independent optimization of each array and uses the silicon area more effectively without any drawback. For imaging experiments, we designed and constructed a custom integrated circuit using a standard 0.5 mu m CMOS process for data acquisition. A sample pulse-echo signal received from the oil-air Interface (plane reflector) at 6mm had a center frequency of 11MHz with 95% fractional 6-dB bandwidth. The measured SNR of the echo was 24 dB with no averaging. B-scan image of a wire-phantom was generated to test the resolution.en_US
dc.language.isoengen_US
dc.publisherIEEEen_US
dc.relation.ispartofseriesUltrasonics Symposiumen_US
dc.relation.isversionof10.1109/ULTSYM.2007.313
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectA-centeren_US
dc.subjectAnnular ringsen_US
dc.subjectApplication specific integrated circuitsen_US
dc.subjectBandwidthen_US
dc.subjectBeamformingen_US
dc.subjectBiomedical electronicsen_US
dc.subjectBiomedical transducersen_US
dc.subjectBiomedical ultrasonicsen_US
dc.subjectBlood vesselsen_US
dc.subjectBondingen_US
dc.subjectBondpadsen_US
dc.subjectB-scan imageen_US
dc.subjectCapacitive micromachineden_US
dc.subjectCapacitive micromachined ultrasound transducer designen_US
dc.subjectCapacitive sensorsen_US
dc.subjectCMOS integrated circuitsen_US
dc.subjectCMOS processen_US
dc.subjectCMOS processingen_US
dc.subjectCMUTen_US
dc.subjectData acquisitionen_US
dc.subjectDual-annular ring CMUT arrayen_US
dc.subjectElectronics industryen_US
dc.subjectForward-looking IVUS imagingen_US
dc.subjectFrequencyen_US
dc.subjectFrequency 11 MHzen_US
dc.subjectImage resolutionen_US
dc.subjectImaging experimentsen_US
dc.subjectImaging systemsen_US
dc.subjectIntegrated circuit measurementsen_US
dc.subjectIntegrated circuitsen_US
dc.subjectIntravascular ultrasounden_US
dc.subjectIntravascular ultrasound imagingen_US
dc.subjectLithographyen_US
dc.subjectMicrosensorsen_US
dc.subjectNonmetalsen_US
dc.subjectOil-airen_US
dc.subjectOil-air interfaceen_US
dc.subjectPhantomsen_US
dc.subjectPlane reflectoren_US
dc.subjectPulse echoesen_US
dc.subjectPulse-echo signalen_US
dc.subjectReceive ring arraysen_US
dc.subjectRing arraysen_US
dc.subjectSien_US
dc.subjectSiliconen_US
dc.subjectSilicon areaen_US
dc.subjectSilicon substratesen_US
dc.subjectSize 0.5 mumen_US
dc.subjectStandardsen_US
dc.subjectTestingen_US
dc.subjectTransmit ring arraysen_US
dc.subjectUltrasonic imagingen_US
dc.subjectUltrasonic transducer arraysen_US
dc.subjectUltrasonic transducersen_US
dc.subjectUltrasonicsen_US
dc.subjectWire phantomen_US
dc.titleForward-looking IVUS imaging using a dual-annular ring CMUT array: Experimental resultsen_US
dc.typeconferenceObjecten_US
dc.description.versionPublisher's Versionen_US
dc.relation.journal2007 IEEE Ultrasonics Symposium Proceedingsen_US
dc.contributor.departmentIşık Üniversitesi, Mühendislik Fakültesi, Elektrik-Elektronik Mühendisliği Bölümüen_US
dc.contributor.departmentIşık University, Faculty of Engineering, Department of Electrical-Electronics Engineeringen_US
dc.contributor.authorID0000-0002-2357-4424
dc.identifier.startpage1247
dc.identifier.endpage1250
dc.peerreviewedYesen_US
dc.publicationstatusPublisheden_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorTekeş, Coşkunen_US
dc.contributor.institutionauthorKaraman, Mustafaen_US
dc.relation.indexWOSen_US
dc.relation.indexScopusen_US
dc.relation.indexConference Proceedings Citation Index – Science (CPCI-S)en_US
dc.description.wosidWOS:000254281801061


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster