Basit öğe kaydını göster

dc.contributor.authorTekeş, Coşkunen_US
dc.contributor.authorZahorian, Jaime S.en_US
dc.contributor.authorXu, Tobyen_US
dc.contributor.authorRashid, Muhammad Wasequren_US
dc.contributor.authorSatır, Sarpen_US
dc.contributor.authorGürün, Gökçeen_US
dc.contributor.authorKaraman, Mustafaen_US
dc.contributor.authorHasler, Jennifer Olsonen_US
dc.contributor.authorDeğertekin, Fahrettin Leventen_US
dc.date.accessioned2019-08-31T12:10:23Z
dc.date.accessioned2019-08-05T16:04:57Z
dc.date.available2019-08-31T12:10:23Z
dc.date.available2019-08-05T16:04:57Z
dc.date.issued2013
dc.identifier.citationTekeş, C., Zahorian, J., Xu, T., Rashid, M. W., Satir, S., Gürün, G., . . . Değertekin, F. L. (2012). CMUT-based volumetric ultrasonic imaging array design for forward looking ICE and IVUS applications. Paper presented at the Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 8675, 1603-1606. doi:10.1117/12.2007042en_US
dc.identifier.isbn9780819494498
dc.identifier.issn1605-7422
dc.identifier.urihttps://hdl.handle.net/11729/1918
dc.identifier.urihttps://dx.doi.org/10.1117/12.2007042
dc.description.abstractDesigning a mechanically flexible catheter based volumetric ultrasonic imaging device for intravascular and intracardiac imaging is challenging due to small transducer area and limited number of cables. With a few parallel channels, synthetic phased array processing is necessary to acquire data from a large number of transducer elements. This increases the data collection time and hence reduces frame rate and causes artifacts due to tissue-transducer motion. Some of these drawbacks can be resolved by different array designs offered by CMUT-on-CMOS approach. We recently implemented a 2.1-mm diameter single chip 10 MHz dual ring CMUT-on-CMOS array for forward looking ICE with 64-transmit and 56-receive elements along with associated electronics. These volumetric arrays have the small element size required by high operating frequencies and achieve sub mm resolution, but the system would be susceptible to motion artifacts. To enable real time imaging with high SNR, we designed novel arrays consisting of multiple defocused annular rings for transmit aperture and a single ring receive array. The annular transmit rings are utilized to act as a high power element by focusing to a virtual ring shaped line behind the aperture. In this case, image reconstruction is performed by only receive beamforming, reducing total required firing steps from 896 to 14 with a trade-off in image resolution. The SNR of system is improved more than 5 dB for the same frequency and frame rate as compared to the dual ring array, which can be utilized to achieve the same resolution by increasing the operating frequency.en_US
dc.language.isoengen_US
dc.publisherSPIE-Int Soc Optical Engineeringen_US
dc.relation.isversionof10.1117/12.2007042
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAntenna phased arraysen_US
dc.subjectCMUTen_US
dc.subjectEchocardiographyen_US
dc.subjectImaging systemsen_US
dc.subjectIntracardiac echocardiographiesen_US
dc.subjectIntracardiac echocardiographyen_US
dc.subjectIntravascular ultrasounden_US
dc.subjectMedical imagingen_US
dc.subjectReal timeen_US
dc.subjectSignal to noise ratioen_US
dc.subjectTissueen_US
dc.subjectTomographyen_US
dc.subjectTransducersen_US
dc.subjectUltrasonic imagingen_US
dc.subjectUltrasonicsen_US
dc.subjectImage reconstructionen_US
dc.subjectImage resolutionen_US
dc.subjectVolumetric imagingen_US
dc.titleCMUT-based volumetric ultrasonic imaging array design for forward looking ICE and IVUS applicationsen_US
dc.typeconferenceObjecten_US
dc.description.versionPublisher's Versionen_US
dc.relation.journalProgress in Biomedical Optics and Imaging - Proceedings of SPIEen_US
dc.contributor.departmentIşık Üniversitesi, Mühendislik Fakültesi, Elektrik-Elektronik Mühendisliği Bölümüen_US
dc.contributor.departmentIşık University, Faculty of Engineering, Department of Electrical-Electronics Engineeringen_US
dc.identifier.volume8675
dc.identifier.startpage1603
dc.identifier.endpage1606
dc.peerreviewedYesen_US
dc.publicationstatusPublisheden_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorKaraman, Mustafaen_US
dc.relation.indexWOSen_US
dc.relation.indexScopusen_US
dc.relation.indexConference Proceedings Citation Index – Science (CPCI-S)en_US
dc.description.wosidWOS:000325266100008


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster