dc.contributor.author | Güldiken, Rasim Oytun | en_US |
dc.contributor.author | Zahorian, Jaime S. | en_US |
dc.contributor.author | Karaman, Mustafa | en_US |
dc.contributor.author | Değertekin, Fahrettin Levent | en_US |
dc.date.accessioned | 2019-08-31T12:10:23Z | |
dc.date.accessioned | 2019-08-05T16:05:02Z | |
dc.date.available | 2019-08-31T12:10:23Z | |
dc.date.available | 2019-08-05T16:05:02Z | |
dc.date.issued | 2007 | |
dc.identifier.citation | Güldiken, R. O., Zahorian, J. S., Karaman, M. & Değertekin, F. L. (2007). Dual electrode capacitive micromachined ultrasonic transducer array for 1-D intracardiac echocardiography (ICE). Paper presented at the 2, 349-350. doi:10.1115/IMECE2007-42480 | en_US |
dc.identifier.isbn | 791842967 | |
dc.identifier.isbn | 9780791842966 | |
dc.identifier.other | WOS:000254463900054 | |
dc.identifier.uri | https://hdl.handle.net/11729/2003 | |
dc.identifier.uri | https://dx.doi.org/10.1115/IMECE2007-42480 | |
dc.description.abstract | We designed and fabricated a 64 element 1-D linear dual electrode Capacitive Micromachined Ultrasonic Transducer (CMUT) array operating at 9.5 MHz for Intracardiac Echocardiography (ICE). The dual electrode CMUT structure increases the overall sensitivity by 12.6dB (6.2dB in receive sensitivity; 6.4dB in output pressure) when compared to optimized single electrode CMUT. We report peak output pressure of 2.3MPa on the CMUT surface when 170V AC and 180V DC is applied. This significant performance increase makes the CMUT more competitive with their piezoelectric counterparts. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | American Society of Mechanical Engineers (ASME) | en_US |
dc.relation.ispartofseries | ASME | en_US |
dc.relation.isversionof | 10.1115/IMECE2007-42480 | |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Capacitance | en_US |
dc.subject | Capacitive micromachined | en_US |
dc.subject | Capacitive micromachined ultrasonic transducer | en_US |
dc.subject | Dual electrode capacitive micromachined ultrasonic transducer arrays | en_US |
dc.subject | Dual electrodes | en_US |
dc.subject | Echocardiography | en_US |
dc.subject | Electrodes | en_US |
dc.subject | Intracardiac echocardiographies | en_US |
dc.subject | Intracardiac Echocardiography (ICE) | en_US |
dc.subject | Micromachining | en_US |
dc.subject | Optimization | en_US |
dc.subject | Pressure | en_US |
dc.subject | Sensitivity analysis | en_US |
dc.subject | Single electrodes | en_US |
dc.subject | Transducers | en_US |
dc.subject | Ultrasonic imaging | en_US |
dc.subject | Ultrasonic transducers | en_US |
dc.title | Dual electrode capacitive micromachined ultrasonic transducer array for 1-D intracardiac echocardiography (ICE) | en_US |
dc.type | conferenceObject | en_US |
dc.description.version | Publisher's Version | en_US |
dc.relation.journal | ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE) | en_US |
dc.contributor.department | Işık Üniversitesi, Mühendislik Fakültesi, Elektrik-Elektronik Mühendisliği Bölümü | en_US |
dc.contributor.department | Işık University, Faculty of Engineering, Department of Electrical-Electronics Engineering | en_US |
dc.identifier.volume | 2 | |
dc.identifier.startpage | 349 | |
dc.identifier.endpage | 350 | |
dc.peerreviewed | Yes | en_US |
dc.publicationstatus | Published | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.contributor.institutionauthor | Karaman, Mustafa | en_US |