• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Işık
  • 1- Fakülteler | Faculties
  • Fen Edebiyat Fakültesi / Faculty of Arts and Sciences
  • Fizik Bölümü / Department of Physics
  • FEF - Makale Koleksiyonu | Fizik Bölümü / Department of Physics
  • Öğe Göster
  •   DSpace@Işık
  • 1- Fakülteler | Faculties
  • Fen Edebiyat Fakültesi / Faculty of Arts and Sciences
  • Fizik Bölümü / Department of Physics
  • FEF - Makale Koleksiyonu | Fizik Bölümü / Department of Physics
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Component resolved OSL dose response and sensitization of various sedimentary quartz samples

Thumbnail

Göster/Aç

Publisher's Version (455.5Kb)

Tarih

2007-02

Yazar

Güneç Kıyak, Nafiye
Polymeris, George S.
Kitis, George

Üst veri

Tüm öğe kaydını göster

Künye

Güneç Kıyak, N., Polymeris, G. S. & Kitis, G. (2007). Component resolved OSL dose response and sensitization of various sedimentary quartz samples. Radiation Measurements, 42(2), 144-155. doi:10.1016/j.radmeas.2007.02.052

Özet

The structure of the linearly modulated optically stimulated luminescence (LM-OSL) signal was studied for four sedimentary quartz samples, collected from different sites around Istanbul, Turkey. Applying a computerized deconvolution analysis to the LM-OSL curves, at least six individual components of first-order kinetics were identified and photoionization cross-section of each component was evaluated. The OSL dose-response curve of each component for each quartz sample was obtained, showing a remarkable differentiation from component to component. The behavior of a highly dosed sample to successive LM-OSL measurements was also studied showing a stable recuperation signal in the position of the "slow" and "medium" components and high resistance to OSL bleaching of the "slow" component. The individual sensitivity of each component as a function of the activation temperature was obtained. The sensitivity of each component was normalized over the respective sensitivity of the glow-peak at 110 degrees C of quartz in order to investigate the ability of the 110 degrees C glow-peak to act as a correction factor for all components of the LM-OSL curves examined.

Kaynak

Radiation Measurements

Cilt

42

Sayı

2

Bağlantı

https://hdl.handle.net/11729/264
http://dx.doi.org/10.1016/j.radmeas.2007.02.052

Koleksiyonlar

  • FEF - Makale Koleksiyonu | Fizik Bölümü / Department of Physics [157]
  • Scopus İndeksli Makale Koleksiyonu [946]
  • WoS İndeksli Makale Koleksiyonu [954]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Işık

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliIşık Yazarına GöreKünyeye GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliIşık Yazarına GöreKünyeye Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber || Kütüphane || Işık Üniversitesi || OAI-PMH ||

Işık Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Şile, İstanbul, Türkiye
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

Creative Commons License
Işık Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Işık:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.