Basit öğe kaydını göster

dc.contributor.authorGüneç Kıyak, Nafiyeen_US
dc.contributor.authorPolymeris, George S.en_US
dc.contributor.authorKitis, Georgeen_US
dc.date.accessioned2015-01-15T23:00:50Z
dc.date.available2015-01-15T23:00:50Z
dc.date.issued2007-02
dc.identifier.citationGüneç Kıyak, N., Polymeris, G. S. & Kitis, G. (2007). Component resolved OSL dose response and sensitization of various sedimentary quartz samples. Radiation Measurements, 42(2), 144-155. doi:10.1016/j.radmeas.2007.02.052en_US
dc.identifier.issn1350-4487
dc.identifier.issn1879-0925
dc.identifier.urihttps://hdl.handle.net/11729/264
dc.identifier.urihttp://dx.doi.org/10.1016/j.radmeas.2007.02.052
dc.description.abstractThe structure of the linearly modulated optically stimulated luminescence (LM-OSL) signal was studied for four sedimentary quartz samples, collected from different sites around Istanbul, Turkey. Applying a computerized deconvolution analysis to the LM-OSL curves, at least six individual components of first-order kinetics were identified and photoionization cross-section of each component was evaluated. The OSL dose-response curve of each component for each quartz sample was obtained, showing a remarkable differentiation from component to component. The behavior of a highly dosed sample to successive LM-OSL measurements was also studied showing a stable recuperation signal in the position of the "slow" and "medium" components and high resistance to OSL bleaching of the "slow" component. The individual sensitivity of each component as a function of the activation temperature was obtained. The sensitivity of each component was normalized over the respective sensitivity of the glow-peak at 110 degrees C of quartz in order to investigate the ability of the 110 degrees C glow-peak to act as a correction factor for all components of the LM-OSL curves examined.en_US
dc.language.isoengen_US
dc.publisherElsevier Ltden_US
dc.relation.isversionof10.1016/j.radmeas.2007.02.052
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectOptically stimulated luminescenceen_US
dc.subjectTlen_US
dc.subjectKoreaen_US
dc.subjectSensitivityen_US
dc.subjectTemperatureen_US
dc.subjectProtocolen_US
dc.subjectLinear modulationen_US
dc.subjectMarine terrace sedimentsen_US
dc.subjectDosimetryen_US
dc.subjectLuminescenceen_US
dc.subjectPhotoionizationen_US
dc.subjectSedimentary rocksen_US
dc.subjectRecuperation signalen_US
dc.subjectSedimentary quartzen_US
dc.subjectQuartzen_US
dc.titleComponent resolved OSL dose response and sensitization of various sedimentary quartz samplesen_US
dc.typearticleen_US
dc.description.versionPublisher's Versionen_US
dc.relation.journalRadiation Measurementsen_US
dc.contributor.departmentIşık Üniversitesi, Fen Edebiyat Fakültesi, Fizik Bölümüen_US
dc.contributor.departmentIşık University, Faculty of Arts and Sciences, Department of Physicsen_US
dc.identifier.volume42
dc.identifier.issue2
dc.identifier.startpage144
dc.identifier.endpage155
dc.peerreviewedYesen_US
dc.publicationstatusPublisheden_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorGüneç Kıyak, Nafiyeen_US
dc.relation.indexWOSen_US
dc.relation.indexScopusen_US
dc.relation.indexScience Citation Index Expanded (SCI-EXPANDED)en_US
dc.description.qualityQ2
dc.description.wosidWOS:000247516300005


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster