Micromachined capacitive transducer arrays for intravascular ultrasound
(SPIE, 2005)
Intravascular ultrasound (IVUS) imaging has become an essential imaging modality for the effective diagnosis and treatment of cardiovascular diseases during the past decade enabled by innovative applications of piezoelectric ...
Frequency selective fading channel estimation in OFDM systems using KL expansion
(IEEE, 2005)
This paper proposes a computationally efficient, linear minimum mean square error (MMSE) channel estimation algorithm based on KL series expansion for OFDM systems. Based on such expansion, no matrix inversion is required ...
Forward-looking IVUS imaging using an annular-ring CMUT array
(IEEE, 2005)
A 64-element, 1.15mm diameter annular-ring CMUT array was characterized and used for forward-looking IVUS imaging tests. The array was manufactured using low temperature processes suitable for CMOS electronics integration ...
A lumped circuit model for the radiation impedance of a 2D CMUT array element
(IEEE, 2005)
Elements of a 2D array used for 3D acoustic imaging have dimensions smaller than half of the acoustic wavelength due to the Nyquist criteria for spatial sampling. Therefore, analyses involving circuit models for the array ...
An endoscopie imaging system based on a two-dimensional CMUT array: real-time imaging results
(IEEE, 2005)
Real-time catheter-based ultrasound imaging tools are needed for diagnosis and image-guided procedures. The continued development of these tools is partially limited by the difficulty of fabricating two-dimensional array ...
A tunable analog delay element for high-frequency dynamic beamforming
(IEEE, 2009)
Implementing beamforming for high frequency arrays is challenging because of the accurate delay requirements at high frequencies. High frequency digital beamforming is not suitable for catheter based applications as a large ...
Wavelet-based image compression by hierarchical quantization indexing
(IEEE, 2009)
In this paper, we introduce the quantization index hierarchy, which is used for efficient coding of quantized wavelet coefficients. A hierarchical classification map is defined in each wavelet subband, which describes the ...
Co-array optimization of CMUT arrays for forward-looking IVUS
(IEEE, 2009-09)
The ring annular array structure is a preferred configuration for implementing Forward-Looking IVUS (FLIVUS) catheters as it allows for volumetric imaging as well as use of a guidewire at the center. CMUT technology is ...
Front-end CMOS electronics for monolithic integration with CMUT arrays: Circuit design and initial experimental results
(2008)
This paper discusses design of CMOS-ASICs for monolithic integration of CMUT arrays by post-CMOS fabrication. We describe design strategies for monolithic integration and demonstrate the advantages of CMUT-on-CMOS approach. ...
Evaluation of CMUT annular arrays for side-looking IVUS
(IEEE, 2009)
Side-looking (SL) IVUS probes are extensively used for management of cardiovascular diseases. Currently SL-IVUS imaging probes use either a single rotating transducer element or solid-state arrays. Probes with single ...