Minimally redundant 2-D array designs for 3-D medical ultrasound imaging
(IEEE-Inst Electrical Electronics Engineers Inc, 2009-07)
In real-time ultrasonic 3-D imaging, in addition to difficulties in fabricating and interconnecting 2-D transducer arrays with hundreds of elements, there are also challenges in acquiring and processing data from a large ...
Monolithic CMUT-on-CMOS integration for intravascular ultrasound applications
(IEEE-INST Electrical Electronics Engineers Inc, 2011-12)
One of the most important promises of capacitive micromachined ultrasonic transducer (CMUT) technology is integration with electronics. This approach is required to minimize the parasitic capacitances in the receive mode, ...
An integrated circuit with transmit beamforming flip-chip bonded to a 2-D CMUT array for 3-D ultrasound imaging
(IEEE-INST Electrical Electronics Engineers Inc, 2009-10)
State-of-the-art 3-D medical ultrasound imaging requires transmitting and receiving ultrasound using a 2-D array of ultrasound transducers with hundreds or thousands of elements. A tight combination of the transducer array ...
Damariçi yanal kesit görüntüleme için farklı prob yapılarının incelenmesi
(IEEE, 2009-06-26)
Bu çalışmada dönen bir şaftın yanal yüzeyine yerleştirilmiş 8 adet içiçe halka elemanlardan oluşan yana bakan görüntüleme için yeni bir kateter yapısı incelenmiştir. Bu Katater mimarisi basit bir dizi önü alıcı verici ...
Volumetric ultrasound imaging using 2-D CMUT arrays
(IEEE-Inst Electrical Electronics Engineers Inc, 2003-11)
Recently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as a candidate to overcome the difficulties in the realization of 2-D arrays for real-time 3-D imaging. In this paper, we present the first ...
Forward-viewing CMUT arrays for medical Imaging
(IEEE-INST Electrical Electronics Engineers Inc, 2004-07)
This paper reports the design and testing of forward-viewing annular arrays fabricated using capacitive micromachined ultrasonic transducer (CMUT) technology. Recent research studies have shown that CMUTs have broad frequency ...
Design of a front-end integrated circuit for 3D acoustic imaging using 2D CMUT arrays
(IEEE-INST Electrical Electronics Engineers Inc, 2005-12)
Integration of front-end electronics with 2D capacitive micromachined ultrasonic transducer (CMUT) arrays has been a challenging issue due to the small element size and large channel count. We present design and verification ...
Coherent array imaging using phased subarrays. Part II: Simulations and experimental results
(IEEE-INST Electrical Electronics Engineers Inc, 2005-01)
The basic principles and theory of phased subarray (PSA) imaging imaging provides the flexibility of reducing I he number of front-end hardware channels between that of classical synthetic aperture (CSA) imaging-which uses ...
Annular-ring CMUT arrays for forward-looking IVUS: Transducer characterization and imaging
(IEEE, 2006-02)
In this study, a 64-element, 1.15-mm diameter annular-ring capacitive micromachined ultrasonic transducer (CMUT) array was characterized and used for forward-looking intravascular ultrasound (IVUS) imaging tests. The array ...
Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging
(IEEE-INST Electrical Electronics Engineers Inc, 2008-02)
For three-dimensional (3D) ultrasound imaging, connecting elements of a two-dimensional (2D) transducer array to the imaging system's front-end electronics is a challenge because of the large number of array elements and ...