Coherent-array imaging using phased subarrays. Part I: Basic principles
(IEEE-INST Electrical Electronics Engineers Inc, 2005-01)
The front-end hardware complexity of a coherent array imaging system scales with the number of active array elements that are simultaneously used for transmission or reception of signals. Different imaging methods use ...
Annular-ring CMUT arrays for forward-looking IVUS: Transducer characterization and imaging
(IEEE, 2006-02)
In this study, a 64-element, 1.15-mm diameter annular-ring capacitive micromachined ultrasonic transducer (CMUT) array was characterized and used for forward-looking intravascular ultrasound (IVUS) imaging tests. The array ...
An analog integrated circuit beamformer for high-frequency medical ultrasound imaging
(IEEE-INST Electrical Electronics Engineers Inc, 2012-10)
We designed and fabricated a dynamic receive beamformer integrated circuit (IC) in 0.35-mu m CMOS technology. This beamformer IC is suitable for integration with an annular array transducer for high-frequency (30-50 MHz) ...
Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging
(IEEE-INST Electrical Electronics Engineers Inc, 2008-02)
For three-dimensional (3D) ultrasound imaging, connecting elements of a two-dimensional (2D) transducer array to the imaging system's front-end electronics is a challenge because of the large number of array elements and ...
Tıbbi ultrasonik kanal içi görüntüleme için yeni yöntemler
(Tübitak, 2008-09)
Yakın zamanda yapılan çalışmalarımızdaki yaklaşımda, aktif kanal sayısını azaltmak için fazlalık (redundant) gönderme-alma eleman ikilileri azalırken gerekli olan (non-redundant) gönderme-alma eleman ikilileri korunmaktadır. ...
Thermoacoustic image reconstruction based on layered tissue model
(SPIE-Int Soc Optical Engineering, 2017)
We derived analytical forward and inverse solution of thermoacoustic wave equation for inhomogeneous multi layered planar and cylindrical mediums with the source distribution existing in all layers. These solutions are ...
Cross-sectional thermoacoustic imaging using multi-layer cylindrical media
(IEEE, 2017-11-10)
For cross-sectional two-dimensional thermoacustic imaging of breast and brain, we explored solution of the wave equation using layered tissue model consisting of concentric annular layers on a cylindrical cross-section. ...
An Analog beamformer for integrated high-frequency medical ultrasound imaging
(IEEE, 2011)
We designed and fabricated a dynamic receive beamforming integrated circuit (IC) in 0.35-mu m CMOS technology. This beamformer is suitable for integration with an ultrasound annular array for high-frequency (30-50 MHz) ...
Çok katmanlı düzlemsel ortam için termoakustik dalga denkleminin çözümü
(IEEE, 2017-06-27)
Bu çalışmada, farklı akustik parametrelere sahip çok katmanlı düzlemsel ortam için tüm katmanlarda kaynak dağılımı olduğu varsayımı altında termoakustik dalga denkleminin analitik olarak düz ve ters çözümü elde edilmiştir. ...
Çok katmanlı silindirik yapılar için termoakustik dalga denkleminin ters çözümü
(IEEE, 2017-06-27)
Termoakustik görüntüleme, elektromanyetik enerji uyarımı ile ultrason dalgaları oluşumunu sağlayan yeni bir yöntemdir. Bu sistemin görüntüleme işlemi termoakustik dalga denkleminin ters çözümüne dayanmaktadır. Ters çözümde ...