8 sonuçlar
Arama Sonuçları
Listeleniyor 1 - 8 / 8
Yayın Dual-annular-ring CMUT array for forward-looking IVUS imaging(IEEE, 2006) Güldiken, Rasim Oytun; Zahorian, Jaime; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Tekeş, Coşkun; Şişman, Alper; Karaman, MustafaWe investigate a dual-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. The array consists of separate, concentric transmit and receive ring arrays built on the same silicon substrate. This configuration has the potential for independent optimization of each array and uses the silicon area more effectively without any particular drawback. We designed and fabricated a 1mm diameter test array which consists of 24 transmit and 32 receive elements. We investigated synthetic phased array beamforming with a non-redundant subset (if transmit-receive element pairs of the dual-annular-ring array. For imaging experiments, we designed and constructed a programmable FPGA-based data acquisition and phased array beamforming system. Pulse-echo measurements along with imaging simulations suggest that dual-ring-annular array should provide performance suitable for real-time FLAVUS applications.Yayın Forward-looking IVUS imaging using a dual-annular ring CMUT array: Experimental results(IEEE, 2007) Güldiken, Rasim Oytun; Zahorian, Jaime S.; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Tekeş, Coşkun; Hasler, Paul E.; Karaman, Mustafa; Carlier, Stephane; Değertekin, Fahrettin LeventThis paper presents the experimental results on forward-looking Intravascular ultrasound (FL-IVUS) using dual-annular-ring CMUT arrays. The array has a diameter of 1mm including bondpads which consists of separate, concentric 24 transmit and 32 receive ring arrays built on the same silicon substrate. This configuration has the potential for Independent optimization of each array and uses the silicon area more effectively without any drawback. For imaging experiments, we designed and constructed a custom integrated circuit using a standard 0.5 mu m CMOS process for data acquisition. A sample pulse-echo signal received from the oil-air Interface (plane reflector) at 6mm had a center frequency of 11MHz with 95% fractional 6-dB bandwidth. The measured SNR of the echo was 24 dB with no averaging. B-scan image of a wire-phantom was generated to test the resolution.Yayın Annular CMUT arrays for side looking intravascular ultrasound imaging(IEEE, 2007) Zahorian, Jaime; Güldiken, Rasim Oytun; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Carlier, Stephane; Şişman, Alper; Karaman, MustafaAlthough side looking intravascular ultrasound (SL-IVUS) imaging systems using single element piezoelectric transducers set the resolution standard in the assessment of the extent of coronary artery disease, improvements in transducer performance are needed to perform harmonic imaging and high resolution imaging of vulnerable plaque. With their small channel count; annular arrays exploiting the inherent broad bandwidth of CMUTs and electronic focusing capability of integrated electronics provide a path for desired SL-IVUS imaging catheters. In this paper, we first describe the design, low temperature fabrication of an 8401 mu m diameter, 8 element CMUT annular array. Testing of the individual elements in oil shows a uniform device behavior with 100% fractional bandwidth around 20MHz without including the effects of attenuation and diffraction. We also present linear scan imaging results obtained on wire targets in oil, tissue and tissue mimicking phantoms using both unfocused and dynamically focused transducers. The results for axial and lateral resolution are in agreement predicted by the simulations and show the feasibility of this approach for high resolution SL-IVUS imaging.Yayın Forward-looking IVUS imaging using an annular-ring CMUT array(IEEE, 2005) Değertekin, Fahrettin Levent; Karaman, Mustafa; Güldiken, Rasim OytunA 64-element, 1.15mm diameter annular-ring CMUT array was characterized and used for forward-looking IVUS imaging tests. The array was manufactured using low temperature processes suitable for CMOS electronics integration on a single chip. The 43×140µm2 array element has suitable view angle for forward looking imaging around 15MHz center frequency and pulse-echo measurements show nearly 100% fractional bandwidth around 17MHz. For imaging and SNR measurements, RF A-scan data sets from various targets were collected using an interconnect scheme forming a 32-element array configuration. The results demonstrate that annular-ring CMUT arrays fabricated with CMOS compatible processes are capable of forward-looking IVUS imaging.Yayın Dual electrode capacitive micromachined ultrasonic transducer array for 1-D intracardiac echocardiography (ICE)(American Society of Mechanical Engineers (ASME), 2007) Güldiken, Rasim Oytun; Zahorian, Jaime S.; Karaman, Mustafa; Değertekin, Fahrettin LeventWe designed and fabricated a 64 element 1-D linear dual electrode Capacitive Micromachined Ultrasonic Transducer (CMUT) array operating at 9.5 MHz for Intracardiac Echocardiography (ICE). The dual electrode CMUT structure increases the overall sensitivity by 12.6dB (6.2dB in receive sensitivity; 6.4dB in output pressure) when compared to optimized single electrode CMUT. We report peak output pressure of 2.3MPa on the CMUT surface when 170V AC and 180V DC is applied. This significant performance increase makes the CMUT more competitive with their piezoelectric counterparts.Yayın Micromachined capacitive transducer arrays for intravascular ultrasound(SPIE, 2005) Değertekin, Fahrettin Levent; Güldiken, Rasim Oytun; Karaman, MustafaIntravascular ultrasound (IVUS) imaging has become an essential imaging modality for the effective diagnosis and treatment of cardiovascular diseases during the past decade enabled by innovative applications of piezoelectric transducer technology. The limitations in the manufacture and performance of the same piezoelectric transducers have also impeded the improvement of IVUS for emerging clinically important applications such as forward viewing arrays for guiding interventions and high resolution imaging of arterial structure such as vulnerable plaque and fibrous cap, and also implementation of techniques such as harmonic imaging of the tissue and of the contrast agents. Capacitive micromachined ultrasonic transducer (CMUT) technology shows great potential for transforming IVUS not only to satisfy these clinical needs but also to open up possibilities for low-cost imaging devices integrated to therapeutic tools. We have developed manufacturing processes with a maximum process temperature of 250°C to build CMUTs on the same silicon chip with integrated electronics. Using these processes we fabricated CMUT arrays suitable for forward viewing IVUS in the 10-20MHz range. We characterized these array elements in terms of pulse-echo response, radiation pattern measurements and demonstrated its volumetric imaging capabilities on various imaging targets.Yayın Multiple annular ring capacitive micromachined ultrasonic transducer arrays for forward-looking intravascular ultrasound imaging catheters(American Society of Mechanical Engineers (ASME), 2007) Güldiken, Rasim Oytun; Zahorian, Jaime S.; Balantekin, Müjdat; Karaman, Mustafa; Değertekin, Fahrettin LeventWe investigate multiple-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. This configuration has the potential for independent optimization of each ring and uses the silicon area more effectively without any particular drawback. We designed and fabricated a sample 1mm diameter dual annular ring CMUT test array which consists of 24 transmit and 32 receive elements. For imaging experiments, we designed IC chips that contain 8 transimpedance amplifiers, a multiplexer and a buffer. The real time-pulse echo experiments obtained with designed IC electronics show 26dB Signal to Noise Ratio (SNR) from a 3.5 mm away aluminum reflector in oil. This paper presents our first efforts in obtaining real time imaging with designed IC chips which is one step before CMUT on CMOS implementation.Yayın A tunable analog delay element for high-frequency dynamic beamforming(IEEE, 2009) Gürün, Gökçe; Şişman, Alper; Zahorian, Jaime S.; Satır, Sarp; Karaman, Mustafa; Hasler, Paul E.; Değertekin, Fahrettin LeventImplementing beamforming for high frequency arrays is challenging because of the accurate delay requirements at high frequencies. High frequency digital beamforming is not suitable for catheter based applications as a large number of cables is required between the array and the external beamformer. A possible solution is to perform analog beamforming on an integrated circuit adjacent or monolithically integrated to the imaging array. In this study, we introduce an improved voltage in voltage out low pass filter as an analog delay cell for high frequency dynamic beamformers. This circuit can generate three times more delay with a given bandwidth when compared to conventional low pass filters. Delay of the circuit is tunable and the gain of the cell is inherently very close to unity. The proposed delay cell operates single ended and therefore is more suitable for CMUT operation which generates single ended output. We designed a test beamformer for a 30MHz, equal area, annular array with 100% bandwidth using the proposed delay cell and the unit-delay focusing architecture. Required delays are implemented using a delay line made up of improved delay elements with tunable delays. To demonstrate functionality we designed and fabricated a custom front-end IC in a 0.5µm standard CMOS process. The IC chip consists of 8 transimpedance amplifiers, voltage-to-current converters, the analog dynamic beamformer, and two buffers. We present results of preliminary imaging experiments that demonstrate the focusing capability.












