5 sonuçlar
Arama Sonuçları
Listeleniyor 1 - 5 / 5
Yayın Dual-annular-ring CMUT array for forward-looking IVUS imaging(IEEE, 2006) Güldiken, Rasim Oytun; Zahorian, Jaime; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Tekeş, Coşkun; Şişman, Alper; Karaman, MustafaWe investigate a dual-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. The array consists of separate, concentric transmit and receive ring arrays built on the same silicon substrate. This configuration has the potential for independent optimization of each array and uses the silicon area more effectively without any particular drawback. We designed and fabricated a 1mm diameter test array which consists of 24 transmit and 32 receive elements. We investigated synthetic phased array beamforming with a non-redundant subset (if transmit-receive element pairs of the dual-annular-ring array. For imaging experiments, we designed and constructed a programmable FPGA-based data acquisition and phased array beamforming system. Pulse-echo measurements along with imaging simulations suggest that dual-ring-annular array should provide performance suitable for real-time FLAVUS applications.Yayın Forward-looking IVUS imaging using a dual-annular ring CMUT array: Experimental results(IEEE, 2007) Güldiken, Rasim Oytun; Zahorian, Jaime S.; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Tekeş, Coşkun; Hasler, Paul E.; Karaman, Mustafa; Carlier, Stephane; Değertekin, Fahrettin LeventThis paper presents the experimental results on forward-looking Intravascular ultrasound (FL-IVUS) using dual-annular-ring CMUT arrays. The array has a diameter of 1mm including bondpads which consists of separate, concentric 24 transmit and 32 receive ring arrays built on the same silicon substrate. This configuration has the potential for Independent optimization of each array and uses the silicon area more effectively without any drawback. For imaging experiments, we designed and constructed a custom integrated circuit using a standard 0.5 mu m CMOS process for data acquisition. A sample pulse-echo signal received from the oil-air Interface (plane reflector) at 6mm had a center frequency of 11MHz with 95% fractional 6-dB bandwidth. The measured SNR of the echo was 24 dB with no averaging. B-scan image of a wire-phantom was generated to test the resolution.Yayın Annular CMUT arrays for side looking intravascular ultrasound imaging(IEEE, 2007) Zahorian, Jaime; Güldiken, Rasim Oytun; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Carlier, Stephane; Şişman, Alper; Karaman, MustafaAlthough side looking intravascular ultrasound (SL-IVUS) imaging systems using single element piezoelectric transducers set the resolution standard in the assessment of the extent of coronary artery disease, improvements in transducer performance are needed to perform harmonic imaging and high resolution imaging of vulnerable plaque. With their small channel count; annular arrays exploiting the inherent broad bandwidth of CMUTs and electronic focusing capability of integrated electronics provide a path for desired SL-IVUS imaging catheters. In this paper, we first describe the design, low temperature fabrication of an 8401 mu m diameter, 8 element CMUT annular array. Testing of the individual elements in oil shows a uniform device behavior with 100% fractional bandwidth around 20MHz without including the effects of attenuation and diffraction. We also present linear scan imaging results obtained on wire targets in oil, tissue and tissue mimicking phantoms using both unfocused and dynamically focused transducers. The results for axial and lateral resolution are in agreement predicted by the simulations and show the feasibility of this approach for high resolution SL-IVUS imaging.Yayın Front-end CMOS electronics for monolithic integration with CMUT arrays: Circuit design and initial experimental results(2008) Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Güldiken, Rasim Oytun; Zahorian, Jaime S.; Peng, Shengyu; Basu, Arindam; Karaman, Mustafa; Hasler, Paul E.; Değertekin, Fahrettin LeventThis paper discusses design of CMOS-ASICs for monolithic integration of CMUT arrays by post-CMOS fabrication. We describe design strategies for monolithic integration and demonstrate the advantages of CMUT-on-CMOS approach. On the same wafer, separate sets of IC cells are designed to interface different types of CMUT arrays for IVUS and ICE applications. Circuit topologies include resistive feedback transimpedance amplifiers on the receiver side, along with multiplexers and buffers. Gains and bandwidths of receiving amplifiers are optimized separately to fit different array specifications such as number of elements, element size and operation bandwidth. To drive CMUTs a high voltage pulser array is designed in the same 3.3V unmodified CMOS technology by combining existing technological layers in an unconventional way. CMUT arrays are then built on top of the custom made 8" wafer containing these circuits fabricated in a 0.35µm standard CMOS process. We present initial characterization of the CMO electronics and pulse-echo measurements obtained post-CMOS fabricated CMUT elements.Yayın Micromachined capacitive transducer arrays for intravascular ultrasound(SPIE, 2005) Değertekin, Fahrettin Levent; Güldiken, Rasim Oytun; Karaman, MustafaIntravascular ultrasound (IVUS) imaging has become an essential imaging modality for the effective diagnosis and treatment of cardiovascular diseases during the past decade enabled by innovative applications of piezoelectric transducer technology. The limitations in the manufacture and performance of the same piezoelectric transducers have also impeded the improvement of IVUS for emerging clinically important applications such as forward viewing arrays for guiding interventions and high resolution imaging of arterial structure such as vulnerable plaque and fibrous cap, and also implementation of techniques such as harmonic imaging of the tissue and of the contrast agents. Capacitive micromachined ultrasonic transducer (CMUT) technology shows great potential for transforming IVUS not only to satisfy these clinical needs but also to open up possibilities for low-cost imaging devices integrated to therapeutic tools. We have developed manufacturing processes with a maximum process temperature of 250°C to build CMUTs on the same silicon chip with integrated electronics. Using these processes we fabricated CMUT arrays suitable for forward viewing IVUS in the 10-20MHz range. We characterized these array elements in terms of pulse-echo response, radiation pattern measurements and demonstrated its volumetric imaging capabilities on various imaging targets.












