20 sonuçlar
Arama Sonuçları
Listeleniyor 1 - 10 / 20
Yayın Phased subarray imaging for low-cost, wideband coherent array imaging(IEEE, 2003) Johnson, Jeremy A.; Oralkan, Ömer; Ergün, Arif Sanlı; Demirci, Utkan; Karaman, Mustafa; Khuri-Yakub, Butrus ThomasThe front-end hardware complexity of conventional full phased array (FPA) imaging is proportional to the number of array elements. Phased subarray (PSA) imaging has been proposed as a method of reducing the hardware complexity-and therefore system cost and size-while achieving near-FPA image quality. A new method is presented for designing the subarray-dependent interpolation filters suitable for wideband PSA imaging. The method was tested experimentally using pulse-echo data of a wire target phantom acquired using a 3.2-cm. 128-element capacitive micromachined ultrasonic transducer (CMUT) array with 85% fractional bandwidth at 3 MHz. A specific PSA configuration using seven 32-element subarrays was compared to FPA imaging, representing a 4-fold reduction in front-end hardware complexity and a 43% decrease in frame rate. For targets near the fixed transmit focal distance, the mean 6-dB lateral resolution was identical to that of FPA, the axial resolution improved by 4%, and the SNR decreased by 5 dB. Measurements were repeated for 10 different PSA configurations with subarray sizes ranging from 4 to 60. The lateral and axial resolutions did not vary significantly with subarray size; both the SNR and contrast-to-noise ratio (CNR) improved with increased subarray size.Yayın Volumetric ultrasound imaging using 2-D CMUT arrays(IEEE-Inst Electrical Electronics Engineers Inc, 2003-11) Oralkan, Ömer; Ergün, Arif Sanlı; Cheng, Ching-Hsiang; Johnson, Jeremy A.; Karaman, Mustafa; H. Lee, Thomas; Khuri-Yakub, Butrus ThomasRecently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as a candidate to overcome the difficulties in the realization of 2-D arrays for real-time 3-D imaging. In this paper, we present the first volumetric images obtained using a 2-D CMUT array. We have fabricated a 128 x 128-element 2-D CMUT array with through-wafer via interconnects and a 420-mum element pitch. As an experimental prototype, a 32 x 64-element portion of the 128 X 128-element array was diced and flip-chip bonded onto a glass fanout chip. This chip provides individual leads from a central 16 X 16-element portion of the array to surrounding bondpads. An 8 x 16-element poition of the array was used in the experiments along with a 128-channel data acquisition system. For imaging phantoms, we used a 2.37-mm diameter steel sphere located 10 mm from the array center and two 12-mm-thick Plexiglas plates located 20 mm and 60 mm from the array. A 4 X 4 group of elements in the middle of the 8 X 16-element array was used in transmit, and the remaining elements were used to receive the echo signals. The echo signal obtained from the spherical target presented a frequency spectrum centered at 4.37 MHz with a 100% fractional bandwidth, whereas the frequency spectrum for the echo signal from the parallel plate phantom was centered at 3.44 MHz with a 91% fractional bandwidth. The images were reconstructed by using RF beamforming and synthetic phased array approaches and visualized by surface rendering and multiplanar slicing techniques. The image of the spherical target has been used to approximate the point spread function of the system and is compared with theoretical expectations. This study experimentally demonstrates that 2-D CMUT arrays can be fabricated with high yield using silicon IC-fabrication processes, individual electrical connections can be provided using through-wafer vias, and flip-chip bonding can be used to integrate these dense 2-D arrays with electronic circuits for practical 3-D imaging applications.Yayın CMUT-based volumetric ultrasonic imaging array design for forward looking ICE and IVUS applications(SPIE-Int Soc Optical Engineering, 2013) Tekeş, Coşkun; Zahorian, Jaime S.; Xu, Toby; Rashid, Muhammad Wasequr; Satır, Sarp; Gürün, Gökçe; Karaman, Mustafa; Hasler, Jennifer Olson; Değertekin, Fahrettin LeventDesigning a mechanically flexible catheter based volumetric ultrasonic imaging device for intravascular and intracardiac imaging is challenging due to small transducer area and limited number of cables. With a few parallel channels, synthetic phased array processing is necessary to acquire data from a large number of transducer elements. This increases the data collection time and hence reduces frame rate and causes artifacts due to tissue-transducer motion. Some of these drawbacks can be resolved by different array designs offered by CMUT-on-CMOS approach. We recently implemented a 2.1-mm diameter single chip 10 MHz dual ring CMUT-on-CMOS array for forward looking ICE with 64-transmit and 56-receive elements along with associated electronics. These volumetric arrays have the small element size required by high operating frequencies and achieve sub mm resolution, but the system would be susceptible to motion artifacts. To enable real time imaging with high SNR, we designed novel arrays consisting of multiple defocused annular rings for transmit aperture and a single ring receive array. The annular transmit rings are utilized to act as a high power element by focusing to a virtual ring shaped line behind the aperture. In this case, image reconstruction is performed by only receive beamforming, reducing total required firing steps from 896 to 14 with a trade-off in image resolution. The SNR of system is improved more than 5 dB for the same frequency and frame rate as compared to the dual ring array, which can be utilized to achieve the same resolution by increasing the operating frequency.Yayın Evaluation of CMUT annular arrays for side-looking IVUS(IEEE, 2009) Şişman, Alper; Zahorian, Jaime S.; Gürün, Gökçe; Karaman, Mustafa; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Hasler, Paul E.Side-looking (SL) IVUS probes are extensively used for management of cardiovascular diseases. Currently SL-IVUS imaging probes use either a single rotating transducer element or solid-state arrays. Probes with single rotating piezoelectric transducer have simple front-end, but have fixed focused operation, and suffers from motion artifacts. Solid-state SL-IVUS imaging probes use piezoelectric transducer arrays and electronic beam-forming. Synthetic phased array processing of signals detected with small-sized elements in these arrays limits the SNR achievable with these probes. In this study, we explore a new SL-IVUS probe architecture employing rotating phased annular CMUT arrays. We tested and compared imaging performance of the existing and proposed probe configurations through simulated point spread functions. We also two fabricated sample annular array designs operating at 20-MHz and 50-MHz. Our experimental measurements on the 20-MHz array in oil shows 105% fractional bandwidth. The 50-MHz array with parylene coating shows approximately 40% fractional bandwidth measured in water. We also present imaging results acquired from wire-targets to test the experimental point-spread functions.Yayın An integrated circuit with transmit beamforming flip-chip bonded to a 2-D CMUT array for 3-D ultrasound imaging(IEEE-INST Electrical Electronics Engineers Inc, 2009-10) Wygant, Ira O.; Jamal, Nafis S.; Lee, Hyunjoo J.; Nikoozadeh, Amin; Oralkan, Ömer; Karaman, Mustafa; Khuri-Yakub, Butrus ThomasState-of-the-art 3-D medical ultrasound imaging requires transmitting and receiving ultrasound using a 2-D array of ultrasound transducers with hundreds or thousands of elements. A tight combination of the transducer array with integrated circuitry eliminates bulky cables connecting the elements of the transducer array to a separate system of electronics. Furthermore, preamplifiers located close to the array can lead to improved receive sensitivity. A combined IC and transducer array can lead to a portable, high-performance, and inexpensive 3-D ultrasound imaging system. This paper presents an IC flip-chip bonded to a 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array for 3-D ultrasound imaging. The IC includes a transmit beamformer that generates 25-V unipolar pulses with programmable focusing delays to 224 of the 256 transducer elements. One-shot circuits allow adjustment of the pulse widths for different ultrasound transducer center frequencies. For receiving reflected ultrasound signals, the IC uses the 32-elements along the array diagonals. The IC provides each receiving element with a low-noise 25-MHz-bandwidth transimpedance amplifier. Using a field-programmable gate array (FPGA) clocked at 100 MHz to operate the IC, the IC generated property timed transmit pulses with 5-ns accuracy. With the IC flip-chip bonded to a CMUT array, we show that the IC can produce steered and focused ultrasound beams. We present 2-D and 3-D images of a wire phantom and 2-D orthogonal cross-sectional images (B-scans) of a latex heart phantom.Yayın Damariçi yanal kesit görüntüleme için farklı prob yapılarının incelenmesi(IEEE, 2009-06-26) Şişman, Alper; Karaman, MustafaBu çalışmada dönen bir şaftın yanal yüzeyine yerleştirilmiş 8 adet içiçe halka elemanlardan oluşan yana bakan görüntüleme için yeni bir kateter yapısı incelenmiştir. Bu Katater mimarisi basit bir dizi önü alıcı verici elektroniği ile değişken odaklama olanağı sağlamaktadır. Önerilen mimari, mevcut iki farklı kateter mimarisiyle benzetim sonuçları ile karşılaştırmalı olarak incelenmiştir. Benzetimlerde görüntüleme kateter çapı 1mm alınmış, farklı derinlikler ve açılar için 3 noktasal yansıtıcı ile NDF çıkarılmıştır.Yayın Design of a front-end integrated circuit for 3D acoustic imaging using 2D CMUT arrays(IEEE-INST Electrical Electronics Engineers Inc, 2005-12) Çiçek, İhsan; Bozkurt, Ayhan; Karaman, MustafaIntegration of front-end electronics with 2D capacitive micromachined ultrasonic transducer (CMUT) arrays has been a challenging issue due to the small element size and large channel count. We present design and verification of a front-end drive-readout integrated circuit for 3D ultrasonic imaging using 2D CMUT arrays. The circuit cell dedicated to a single CMUT array element consists of a high-voltage pulser and a low-noise readout amplifier. To analyze the circuit cell together with the CMUT element, we developed an electrical CMUT model with parameters derived through finite element analysis, and performed both the pre- and postlayout verification. An experimental chip consisting of 4 x 4 array of the designed circuit cells, each cell occupying a 200 x 200 mu m(2) area, was formed for the initial test studies and scheduled for fabrication in 0.8 mu m, 50 V CMOS technology. The designed circuit is suitable for integration with CMUT arrays through flip-chip bonding and the CMUT-on-CMOS process.Yayın Forward-viewing CMUT arrays for medical Imaging(IEEE-INST Electrical Electronics Engineers Inc, 2004-07) Demirci, Utkan; Ergün, Arif Sanlı; Oralkan, Ömer; Karaman, Mustafa; Khuri-Yakub, Butrus ThomasThis paper reports the design and testing of forward-viewing annular arrays fabricated using capacitive micromachined ultrasonic transducer (CMUT) technology. Recent research studies have shown that CMUTs have broad frequency bandwidth and high-transduction efficiency. One- and two-dimensional CMUT arrays of various sizes already have been fabricated, and their viability for medical imaging applications has been demonstrated. We fabricated 64-element, forward-viewing annular arrays using the standard CMUT fabrication process and carried out experiments to measure the operating frequency, bandwidth, and transmit/receive efficiency of the array elements. The annular array elements, designed for imaging applications in the 20 MHz range, had a resonance frequency of 13.5 MHz in air. The immersion pulse-echo data collected from a plane reflector showed that the devices operate in the 5-26 MHz range with a fractional bandwidth of 135%. The output pressure at the surface of the transducer was measured to be 24 kPa/V. These values translate into a dynamic range of 131.5 dB for I-V excitation in 1-Hz bandwidth with a commercial low noise receiving circuitry. The designed, forward-viewing annular CMUT array is suitable for mounting on the front surface of a cylindrical catheter probe and can provide Doppler information for measurement of blood flow and guiding information for navigation through blood vessels in intravascular ultrasound imaging.Yayın Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging(IEEE-INST Electrical Electronics Engineers Inc, 2008-02) Wygant, Ira O.; Zhuang, Xuefeng; Yeh, David T.; Oralkan, Ömer; Ergün, Arif Sanlı; Karaman, Mustafa; Khuri-Yakub, Butrus ThomasFor three-dimensional (3D) ultrasound imaging, connecting elements of a two-dimensional (2D) transducer array to the imaging system's front-end electronics is a challenge because of the large number of array elements and the small element size. To compactly connect the transducer array with electronics, we flip-chip bond a 2D 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array to a custom-designed integrated circuit (IC). Through-wafer interconnects are used to connect the CMUT elements on the top side of the array with flip-chip bond pads on the back side. The IC provides a 25-V pulser and a transimpedance preamplifier to each element of the array. For each of three characterized devices, the element yield is excellent (99 to 100% of the elements are functional). Center frequencies range from 2.6 MHz to 5.1 MHz. For pulse-echo operation, the average -6-dB fractional bandwidth is as high as 125%. Transmit pressures normalized to the face of the transducer are as high as 339 kPa and input-referred receiver noise is typically 1.2 to 2.1 mPa/root Hz. The flip-chip bonded devices were used to acquire 3D synthetic aperture images of a wire-target phantom. Combining the transducer array and IC, as shown in this paper, allows for better utilization of large arrays, improves receive sensitivity, and may lead to new imaging techniques that depend on transducer arrays that are closely coupled to IC electronics.Yayın Monolithic CMUT-on-CMOS integration for intravascular ultrasound applications(IEEE-INST Electrical Electronics Engineers Inc, 2011-12) Zahorian, Jaime S.; Hochman, Michael; Xu, Toby; Satır, Sarp; Gürün, Gökçe; Karaman, Mustafa; Değertekin, Fahrettin LeventOne of the most important promises of capacitive micromachined ultrasonic transducer (CMUT) technology is integration with electronics. This approach is required to minimize the parasitic capacitances in the receive mode, especially in catheter-based volumetric imaging arrays, for which the elements must be small. Furthermore, optimization of the available silicon area and minimized number of connections occurs when the CMUTs are fabricated directly above the associated electronics. Here, we describe successful fabrication and performance evaluation of CMUT arrays for intravascular imaging on custom-designed CMOS receiver electronics from a commercial IC foundry. The CMUT-on-CMOS process starts with surface isolation and mechanical planarization of the CMOS electronics to reduce topography. The rest of the CMUT fabrication is achieved by modifying a low-temperature micromachining process through the addition of a single mask and developing a dry etching step to produce sloped sidewalls for simple and reliable CMUT-to-CMOS interconnection. This CMUT-to-CMOS interconnect method reduced the parasitic capacitance by a factor of 200 when compared with a standard wire-bonding method. Characterization experiments indicate that the CMUT-on-CMOS elements are uniform in frequency response and are similar to CMUTs simultaneously fabricated on standard silicon wafers without electronics integration. Experiments on a 1.6-mm-diameter dual-ring CMUT array with a center frequency of 15 MHz show that both the CMUTs and the integrated CMOS electronics are fully functional. The SNR measurements indicate that the performance is adequate for imaging chronic total occlusions located 1 cm from the CMUT array.












