    Forward-looking IVUS imaging using a dual-annular ring CMUT array: Experimental results
    (IEEE, 2007) Güldiken, Rasim Oytun; Zahorian, Jaime S.; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Tekeş, Coşkun; Hasler, Paul E.; Karaman, Mustafa; Carlier, Stephane; Değertekin, Fahrettin Levent
    This paper presents the experimental results on forward-looking Intravascular ultrasound (FL-IVUS) using dual-annular-ring CMUT arrays. The array has a diameter of 1mm including bondpads which consists of separate, concentric 24 transmit and 32 receive ring arrays built on the same silicon substrate. This configuration has the potential for Independent optimization of each array and uses the silicon area more effectively without any drawback. For imaging experiments, we designed and constructed a custom integrated circuit using a standard 0.5 mu m CMOS process for data acquisition. A sample pulse-echo signal received from the oil-air Interface (plane reflector) at 6mm had a center frequency of 11MHz with 95% fractional 6-dB bandwidth. The measured SNR of the echo was 24 dB with no averaging. B-scan image of a wire-phantom was generated to test the resolution.
  • Yayın
    Dual electrode capacitive micromachined ultrasonic transducer array for 1-D intracardiac echocardiography (ICE)
    (American Society of Mechanical Engineers (ASME), 2007) Güldiken, Rasim Oytun; Zahorian, Jaime S.; Karaman, Mustafa; Değertekin, Fahrettin Levent
    We designed and fabricated a 64 element 1-D linear dual electrode Capacitive Micromachined Ultrasonic Transducer (CMUT) array operating at 9.5 MHz for Intracardiac Echocardiography (ICE). The dual electrode CMUT structure increases the overall sensitivity by 12.6dB (6.2dB in receive sensitivity; 6.4dB in output pressure) when compared to optimized single electrode CMUT. We report peak output pressure of 2.3MPa on the CMUT surface when 170V AC and 180V DC is applied. This significant performance increase makes the CMUT more competitive with their piezoelectric counterparts.
  • Yayın
    Multiple annular ring capacitive micromachined ultrasonic transducer arrays for forward-looking intravascular ultrasound imaging catheters
    (American Society of Mechanical Engineers (ASME), 2007) Güldiken, Rasim Oytun; Zahorian, Jaime S.; Balantekin, Müjdat; Karaman, Mustafa; Değertekin, Fahrettin Levent
    We investigate multiple-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. This configuration has the potential for independent optimization of each ring and uses the silicon area more effectively without any particular drawback. We designed and fabricated a sample 1mm diameter dual annular ring CMUT test array which consists of 24 transmit and 32 receive elements. For imaging experiments, we designed IC chips that contain 8 transimpedance amplifiers, a multiplexer and a buffer. The real time-pulse echo experiments obtained with designed IC electronics show 26dB Signal to Noise Ratio (SNR) from a 3.5 mm away aluminum reflector in oil. This paper presents our first efforts in obtaining real time imaging with designed IC chips which is one step before CMUT on CMOS implementation.
  • Yayın
    A tunable analog delay element for high-frequency dynamic beamforming
    (IEEE, 2009) Gürün, Gökçe; Şişman, Alper; Zahorian, Jaime S.; Satır, Sarp; Karaman, Mustafa; Hasler, Paul E.; Değertekin, Fahrettin Levent
    Implementing beamforming for high frequency arrays is challenging because of the accurate delay requirements at high frequencies. High frequency digital beamforming is not suitable for catheter based applications as a large number of cables is required between the array and the external beamformer. A possible solution is to perform analog beamforming on an integrated circuit adjacent or monolithically integrated to the imaging array. In this study, we introduce an improved voltage in voltage out low pass filter as an analog delay cell for high frequency dynamic beamformers. This circuit can generate three times more delay with a given bandwidth when compared to conventional low pass filters. Delay of the circuit is tunable and the gain of the cell is inherently very close to unity. The proposed delay cell operates single ended and therefore is more suitable for CMUT operation which generates single ended output. We designed a test beamformer for a 30MHz, equal area, annular array with 100% bandwidth using the proposed delay cell and the unit-delay focusing architecture. Required delays are implemented using a delay line made up of improved delay elements with tunable delays. To demonstrate functionality we designed and fabricated a custom front-end IC in a 0.5µm standard CMOS process. The IC chip consists of 8 transimpedance amplifiers, voltage-to-current converters, the analog dynamic beamformer, and two buffers. We present results of preliminary imaging experiments that demonstrate the focusing capability.