Arama Sonuçları

Listeleniyor 1 - 2 / 2
  • Yayın
    An endoscopie imaging system based on a two-dimensional CMUT array: real-time imaging results
    (IEEE, 2005) Wygant, Ira O.; Zhuang, Xuefeng; Yeh, David T.; Vaithilingam, Srikant; Nikoozadeh, Amin; Oralkan, Ömer; Ergün, Arif Sanlı; Karaman, Mustafa; Khuri-Yakub, Butrus Thomas
    Real-time catheter-based ultrasound imaging tools are needed for diagnosis and image-guided procedures. The continued development of these tools is partially limited by the difficulty of fabricating two-dimensional array geometries of piezoelectric transducers. Using capacitive micromachined ultrasonic transducer (CMUT) technology, transducer arrays with widely varying geometries, high frequencies, and wide bandwidths can be fabricated. A volumetric ultrasound imaging system based on a two-dimensional, 16×l6-element, CMUT array is presented. Transducer arrays with operating frequencies ranging from 3 MHz to 7.5 MHz were fabricated for this system. The transducer array including DC bias pads measures 4 mm by 4.7 mm. The transducer elements are connected to flip-chip bond pads on the array back side with 400-?m long through-wafer interconnects. The array is flip-chip bonded to a custom-designed integrated circuit (IC) that comprises the front-end electronics. Integrating the front-end electronics with the transducer array reduces the effects of cable capacitance on the transducer's performance and provides a compact means of connecting to the transducer elements. The front-end IC provides a 27-V pulser and 10-MHz bandwidth amplifier for each element of the array. An FPGA-based data acquisition system is used for control and data acquisition. Output pressure of 230 kPa was measured for the integrated device. A receive sensitivity of 125 mV/kPa was measured at the output of the amplifier. Amplifier output noise at 5 Mhz is 112 nV/?Hz. Volumetric images of a wire phantom and vessel phantom are presented. Volumetric data for a wire phantom was acquired in real-time at 30 frames per second.
  • Yayın
    Üç boyutlu akustik görüntüleme için ön alıcı-verici tümdevre
    (IEEE, 2004) Çiçek, İhsan; Bozkurt, Ayhan; Karaman, Mustafa
    Tıbbi ultrasonik görüntüleme sistemleri, genel olarak bir çevirici elemanı ve akustik işaretin üretilip algılanmasından sorumlu elektronik oluşmaktadır. Tek boyutlu dönüştürücü dizileriyle, incelenmekte olan ortamın iki boyutlu kesit görüntüsü elde edilmektedir. Dönüştürücü teknolojisindeki son gelişmelerle, iki boyutlu dönüştürücü dizilerinin üretimi gerçekleştirilmiş, böylece üç boyutlu (hacimsel) görüntüleme yapılması mümkün olmuştur[1,2]. Ancak, özellikle Nyquist kriteri, dönüştürücü elemanların boyutlarını sınırladığı için, eleman boyutları oldukça küçülmüştür; bu da algılanan işareti oldukça zayıflatmaktadır. Bu nedenle, kabul edilebilir nitelikteki görüntülerin alınabilmesi için, alıcı-verici elektroniğinin iyileştirilmesi gerekmektedir. Bu çalışmada, iki boyutlu akustik çeviriciler için CMOS tabanlı ön alıcı-verici devresinin tasarımı gerçekleştirilmiştir. Devre, temel olarak, bir yüksek gerilim darbe üretici, alıcı-verici anahtarı, düşük gürültülü ön yükseltici ve dönüştürücü elemanın bağlantı dolgulamasından oluşmaktadır.