Arama Sonuçları

Listeleniyor 1 - 10 / 11
  • Yayın
    CMUT-based volumetric ultrasonic imaging array design for forward looking ICE and IVUS applications
    (SPIE-Int Soc Optical Engineering, 2013) Tekeş, Coşkun; Zahorian, Jaime S.; Xu, Toby; Rashid, Muhammad Wasequr; Satır, Sarp; Gürün, Gökçe; Karaman, Mustafa; Hasler, Jennifer Olson; Değertekin, Fahrettin Levent
    Designing a mechanically flexible catheter based volumetric ultrasonic imaging device for intravascular and intracardiac imaging is challenging due to small transducer area and limited number of cables. With a few parallel channels, synthetic phased array processing is necessary to acquire data from a large number of transducer elements. This increases the data collection time and hence reduces frame rate and causes artifacts due to tissue-transducer motion. Some of these drawbacks can be resolved by different array designs offered by CMUT-on-CMOS approach. We recently implemented a 2.1-mm diameter single chip 10 MHz dual ring CMUT-on-CMOS array for forward looking ICE with 64-transmit and 56-receive elements along with associated electronics. These volumetric arrays have the small element size required by high operating frequencies and achieve sub mm resolution, but the system would be susceptible to motion artifacts. To enable real time imaging with high SNR, we designed novel arrays consisting of multiple defocused annular rings for transmit aperture and a single ring receive array. The annular transmit rings are utilized to act as a high power element by focusing to a virtual ring shaped line behind the aperture. In this case, image reconstruction is performed by only receive beamforming, reducing total required firing steps from 896 to 14 with a trade-off in image resolution. The SNR of system is improved more than 5 dB for the same frequency and frame rate as compared to the dual ring array, which can be utilized to achieve the same resolution by increasing the operating frequency.
  • Yayın
    Evaluation of CMUT annular arrays for side-looking IVUS
    (IEEE, 2009) Şişman, Alper; Zahorian, Jaime S.; Gürün, Gökçe; Karaman, Mustafa; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Hasler, Paul E.
    Side-looking (SL) IVUS probes are extensively used for management of cardiovascular diseases. Currently SL-IVUS imaging probes use either a single rotating transducer element or solid-state arrays. Probes with single rotating piezoelectric transducer have simple front-end, but have fixed focused operation, and suffers from motion artifacts. Solid-state SL-IVUS imaging probes use piezoelectric transducer arrays and electronic beam-forming. Synthetic phased array processing of signals detected with small-sized elements in these arrays limits the SNR achievable with these probes. In this study, we explore a new SL-IVUS probe architecture employing rotating phased annular CMUT arrays. We tested and compared imaging performance of the existing and proposed probe configurations through simulated point spread functions. We also two fabricated sample annular array designs operating at 20-MHz and 50-MHz. Our experimental measurements on the 20-MHz array in oil shows 105% fractional bandwidth. The 50-MHz array with parylene coating shows approximately 40% fractional bandwidth measured in water. We also present imaging results acquired from wire-targets to test the experimental point-spread functions.
  • Yayın
    Dual-annular-ring CMUT array for forward-looking IVUS imaging
    (IEEE, 2006) Güldiken, Rasim Oytun; Zahorian, Jaime; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Tekeş, Coşkun; Şişman, Alper; Karaman, Mustafa
    We investigate a dual-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. The array consists of separate, concentric transmit and receive ring arrays built on the same silicon substrate. This configuration has the potential for independent optimization of each array and uses the silicon area more effectively without any particular drawback. We designed and fabricated a 1mm diameter test array which consists of 24 transmit and 32 receive elements. We investigated synthetic phased array beamforming with a non-redundant subset (if transmit-receive element pairs of the dual-annular-ring array. For imaging experiments, we designed and constructed a programmable FPGA-based data acquisition and phased array beamforming system. Pulse-echo measurements along with imaging simulations suggest that dual-ring-annular array should provide performance suitable for real-time FLAVUS applications.
  • Yayın
    Damar içi öne bakan ultrasonik görüntüleme için eşdeğer dizi örnekleme yöntemleri
    (IEEE, 2009-06-26) Tekeş, Coşkun; Karaman, Mustafa
    Damar içi öne bakan ultrasonik görüntüleme gerçek zamanlı hacimsel (üç boyutlu) görüntülemeye imkan vermesi bakımından yaygın olarak kullanılmaktadır. Damar içi görüntülemede fiziksel boyutların küçük olması nedeniyle alıcı-verici kanal sayısı çok sınırlanmakta ve dolayısıyla yapay evreli dizi teknikleri kullanılmaktadır. Öte yandan, harekete bağlı görüntü bozukluklarını azaltmak için işaret gönderme alma adım sayısının azaltılması gerekmektedir. Bu, eşdeğer dizideki fazlalık frekans bileşenleri azaltılarak sağlanabilir. Bu çalışmada, eşdeğer dizideki fazlalık frekans bileşenlerinin azaltılmasına dayalı farklı örnekleme teknikleri incelenmiştir. Bu tekniklerin görüntü kalitesi 64 elemanlı bir halkasal dizinin asıl ve kontrol eşdeğer dizileri referans alınarak karşılaştırmalı olarak irdelenmiştir. Benzetim sonuçları 64 elemanlı bir halka dizi için 2049 asıl küme, 350 azaltılmış küme 40 dB içinde eşdeğer performans vermektedir.
  • Yayın
    Forward-looking IVUS imaging using a dual-annular ring CMUT array: Experimental results
    (IEEE, 2007) Güldiken, Rasim Oytun; Zahorian, Jaime S.; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Tekeş, Coşkun; Hasler, Paul E.; Karaman, Mustafa; Carlier, Stephane; Değertekin, Fahrettin Levent
    This paper presents the experimental results on forward-looking Intravascular ultrasound (FL-IVUS) using dual-annular-ring CMUT arrays. The array has a diameter of 1mm including bondpads which consists of separate, concentric 24 transmit and 32 receive ring arrays built on the same silicon substrate. This configuration has the potential for Independent optimization of each array and uses the silicon area more effectively without any drawback. For imaging experiments, we designed and constructed a custom integrated circuit using a standard 0.5 mu m CMOS process for data acquisition. A sample pulse-echo signal received from the oil-air Interface (plane reflector) at 6mm had a center frequency of 11MHz with 95% fractional 6-dB bandwidth. The measured SNR of the echo was 24 dB with no averaging. B-scan image of a wire-phantom was generated to test the resolution.
  • Yayın
    Annular CMUT arrays for side looking intravascular ultrasound imaging
    (IEEE, 2007) Zahorian, Jaime; Güldiken, Rasim Oytun; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Carlier, Stephane; Şişman, Alper; Karaman, Mustafa
    Although side looking intravascular ultrasound (SL-IVUS) imaging systems using single element piezoelectric transducers set the resolution standard in the assessment of the extent of coronary artery disease, improvements in transducer performance are needed to perform harmonic imaging and high resolution imaging of vulnerable plaque. With their small channel count; annular arrays exploiting the inherent broad bandwidth of CMUTs and electronic focusing capability of integrated electronics provide a path for desired SL-IVUS imaging catheters. In this paper, we first describe the design, low temperature fabrication of an 8401 mu m diameter, 8 element CMUT annular array. Testing of the individual elements in oil shows a uniform device behavior with 100% fractional bandwidth around 20MHz without including the effects of attenuation and diffraction. We also present linear scan imaging results obtained on wire targets in oil, tissue and tissue mimicking phantoms using both unfocused and dynamically focused transducers. The results for axial and lateral resolution are in agreement predicted by the simulations and show the feasibility of this approach for high resolution SL-IVUS imaging.
  • Yayın
    Front-end CMOS electronics for monolithic integration with CMUT arrays: Circuit design and initial experimental results
    (2008) Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Güldiken, Rasim Oytun; Zahorian, Jaime S.; Peng, Shengyu; Basu, Arindam; Karaman, Mustafa; Hasler, Paul E.; Değertekin, Fahrettin Levent
    This paper discusses design of CMOS-ASICs for monolithic integration of CMUT arrays by post-CMOS fabrication. We describe design strategies for monolithic integration and demonstrate the advantages of CMUT-on-CMOS approach. On the same wafer, separate sets of IC cells are designed to interface different types of CMUT arrays for IVUS and ICE applications. Circuit topologies include resistive feedback transimpedance amplifiers on the receiver side, along with multiplexers and buffers. Gains and bandwidths of receiving amplifiers are optimized separately to fit different array specifications such as number of elements, element size and operation bandwidth. To drive CMUTs a high voltage pulser array is designed in the same 3.3V unmodified CMOS technology by combining existing technological layers in an unconventional way. CMUT arrays are then built on top of the custom made 8" wafer containing these circuits fabricated in a 0.35µm standard CMOS process. We present initial characterization of the CMO electronics and pulse-echo measurements obtained post-CMOS fabricated CMUT elements.
  • Yayın
    An integrated circuit with transmit beamforming and parallel receive channels for real-time three-dimensional ultrasound imaging
    (IEEE, 2006) Wygant, Ira O.; Lee, Hyunjoo J.; Nikoozadeh, Amin; Yeh, David T.; Oralkan, Ömer; Karaman, Mustafa; Khuri-Yakub, Butrus Thomas
    We present the design of an integrated circuit (IC) that will be flip-chip bonded to a 16 x 16-element CMUT array. The IC provides 16 receive channels which can be configured to receive along either of the array diagonals or on any single row of the array. On transmit, all 256 elements can be used to transmit arbitrarily focused beams. Focused transmission with the full array is made possible by on-chip pulsers and memory. A 25-V pulser and 8-bit shift register is provided for each element of the array. Prior to each transmit, new values are loaded into the shift registers. Current-con trolled one-shots control the transmit pulse widths. Circuit simulations and the IC layout are presented. Simulations predict that delay values can be loaded in less than 1.3 mu s and show the generation of precisely timed pulses. The IC is being prepared for submission to National Semiconductor for fabrication in a high-voltage BiCMOS process.
  • Yayın
    An integrated circuit with transmit beamforming and parallel receive channels for 3D ultrasound imaging: testing and characterization
    (IEEE, 2007) Wygant, Ira O.; Jamal, Nafis S.; Lee, Hyunjoo J.; Nikoozadeh, Amin; Zhuang, Xuefeng; Oralkan, Ömer; Ergün, Arif Sanlı; Karaman, Mustafa; Khuri-Yakub, Butrus Thomas
    The cost and complexity of medical ultrasound imaging systems can be reduced by integrating the transducer array with an integrated circuit (IC). By incorporating some of the system's front-end electronics into an IC, bulky cables and costly system electronics can be eliminated. Here we present an IC for 3D intracavital imaging that requires few electrical connections but uses a large fraction of a 16x16-element 2D transducer array to transmit focused ultrasound. To simplify the receive and data acquisition electronics, only the 32 elements along the array diagonals are used as receivers. The IC provides a preamplifier for each receiving element. Each of the 224 transmitting elements is provided an 8-bit shift register, a comparator, and a 25-V pulser. To transmit, a global counter is incremented from 1 to 224; each pulser fires when its stored register value is equal to the global count value. Electrical testing of the fabricated IC shows that it works as designed. The IC was flip-chip bonded to a two-dimensional capacitive micromachined ultrasonic transducer (CMUT) array. A two-dimensional image of a wire target phantom was acquired.
  • Yayın
    Micromachined capacitive transducer arrays for intravascular ultrasound
    (SPIE, 2005) Değertekin, Fahrettin Levent; Güldiken, Rasim Oytun; Karaman, Mustafa
    Intravascular ultrasound (IVUS) imaging has become an essential imaging modality for the effective diagnosis and treatment of cardiovascular diseases during the past decade enabled by innovative applications of piezoelectric transducer technology. The limitations in the manufacture and performance of the same piezoelectric transducers have also impeded the improvement of IVUS for emerging clinically important applications such as forward viewing arrays for guiding interventions and high resolution imaging of arterial structure such as vulnerable plaque and fibrous cap, and also implementation of techniques such as harmonic imaging of the tissue and of the contrast agents. Capacitive micromachined ultrasonic transducer (CMUT) technology shows great potential for transforming IVUS not only to satisfy these clinical needs but also to open up possibilities for low-cost imaging devices integrated to therapeutic tools. We have developed manufacturing processes with a maximum process temperature of 250°C to build CMUTs on the same silicon chip with integrated electronics. Using these processes we fabricated CMUT arrays suitable for forward viewing IVUS in the 10-20MHz range. We characterized these array elements in terms of pulse-echo response, radiation pattern measurements and demonstrated its volumetric imaging capabilities on various imaging targets.