6 sonuçlar
Arama Sonuçları
Listeleniyor 1 - 6 / 6
Yayın CMUT-based volumetric ultrasonic imaging array design for forward looking ICE and IVUS applications(SPIE-Int Soc Optical Engineering, 2013) Tekeş, Coşkun; Zahorian, Jaime S.; Xu, Toby; Rashid, Muhammad Wasequr; Satır, Sarp; Gürün, Gökçe; Karaman, Mustafa; Hasler, Jennifer Olson; Değertekin, Fahrettin LeventDesigning a mechanically flexible catheter based volumetric ultrasonic imaging device for intravascular and intracardiac imaging is challenging due to small transducer area and limited number of cables. With a few parallel channels, synthetic phased array processing is necessary to acquire data from a large number of transducer elements. This increases the data collection time and hence reduces frame rate and causes artifacts due to tissue-transducer motion. Some of these drawbacks can be resolved by different array designs offered by CMUT-on-CMOS approach. We recently implemented a 2.1-mm diameter single chip 10 MHz dual ring CMUT-on-CMOS array for forward looking ICE with 64-transmit and 56-receive elements along with associated electronics. These volumetric arrays have the small element size required by high operating frequencies and achieve sub mm resolution, but the system would be susceptible to motion artifacts. To enable real time imaging with high SNR, we designed novel arrays consisting of multiple defocused annular rings for transmit aperture and a single ring receive array. The annular transmit rings are utilized to act as a high power element by focusing to a virtual ring shaped line behind the aperture. In this case, image reconstruction is performed by only receive beamforming, reducing total required firing steps from 896 to 14 with a trade-off in image resolution. The SNR of system is improved more than 5 dB for the same frequency and frame rate as compared to the dual ring array, which can be utilized to achieve the same resolution by increasing the operating frequency.Yayın Evaluation of CMUT annular arrays for side-looking IVUS(IEEE, 2009) Şişman, Alper; Zahorian, Jaime S.; Gürün, Gökçe; Karaman, Mustafa; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Hasler, Paul E.Side-looking (SL) IVUS probes are extensively used for management of cardiovascular diseases. Currently SL-IVUS imaging probes use either a single rotating transducer element or solid-state arrays. Probes with single rotating piezoelectric transducer have simple front-end, but have fixed focused operation, and suffers from motion artifacts. Solid-state SL-IVUS imaging probes use piezoelectric transducer arrays and electronic beam-forming. Synthetic phased array processing of signals detected with small-sized elements in these arrays limits the SNR achievable with these probes. In this study, we explore a new SL-IVUS probe architecture employing rotating phased annular CMUT arrays. We tested and compared imaging performance of the existing and proposed probe configurations through simulated point spread functions. We also two fabricated sample annular array designs operating at 20-MHz and 50-MHz. Our experimental measurements on the 20-MHz array in oil shows 105% fractional bandwidth. The 50-MHz array with parylene coating shows approximately 40% fractional bandwidth measured in water. We also present imaging results acquired from wire-targets to test the experimental point-spread functions.Yayın Dual-annular-ring CMUT array for forward-looking IVUS imaging(IEEE, 2006) Güldiken, Rasim Oytun; Zahorian, Jaime; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Tekeş, Coşkun; Şişman, Alper; Karaman, MustafaWe investigate a dual-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. The array consists of separate, concentric transmit and receive ring arrays built on the same silicon substrate. This configuration has the potential for independent optimization of each array and uses the silicon area more effectively without any particular drawback. We designed and fabricated a 1mm diameter test array which consists of 24 transmit and 32 receive elements. We investigated synthetic phased array beamforming with a non-redundant subset (if transmit-receive element pairs of the dual-annular-ring array. For imaging experiments, we designed and constructed a programmable FPGA-based data acquisition and phased array beamforming system. Pulse-echo measurements along with imaging simulations suggest that dual-ring-annular array should provide performance suitable for real-time FLAVUS applications.Yayın Experimental study of dual-ring CMUT array optimization for forward-looking IVUS(IEEE, 2011) Tekeş, Coşkun; Zahorian, Jaime; Gürün, Gökçe; Satir, Sarp; Hochman, Michael; Xu, Toby; Rashid, Muhammad Wasequr; Değertekin, Fahrettin Levent; Karaman, MustafaForward-looking (FL) catheters have guiding and volumetric imaging capacities which are highly desirable for IVUS applications. Large channel and firing counts have to be reduced to enable 3-D real-time imaging and simplify front-end electronics. Recently, we have proposed an optimization procedure for dual ring FL arrays which is based on finding an optimal coarray set using the simulated annealing algorithm. The presented algorithm is based on finding a predefined number of optimal firing set which results in elimination of redundant spatial frequencies in the coarray. In this study, we present the experimental demonstration of the proposed method with fabricated single chip CMUT on CMOS system based FL dual ring arrays. The dual ring CMUT arrays were monolithically fabricated on top of CMOS chips which have 25-V pulsers and low-noise transimpedance amplifiers for each transmit and receive array elements. The fabricated CMUT arrays have 56 transmit and 48 receive elements operating at 12 MHz with a 1.4 mm outer diameter. To test the imaging performance of the optimal reduced set, we obtained a 512-element coarray set from the full 2688-element set. In the experiment, we used a phantom of 100-mu m aluminium wires immersed in oil tank. We have reconstructed both 2-D PSFs and B-scan images of wire targets. Experimental results demonstrate that the simulated annealing based optimal firing set achieves acceptable lateral and contrast resolution performances with 1/5 of the full set.Yayın Damar içi öne bakan ultrasonik görüntüleme için eşdeğer dizi örnekleme yöntemleri(IEEE, 2009-06-26) Tekeş, Coşkun; Karaman, MustafaDamar içi öne bakan ultrasonik görüntüleme gerçek zamanlı hacimsel (üç boyutlu) görüntülemeye imkan vermesi bakımından yaygın olarak kullanılmaktadır. Damar içi görüntülemede fiziksel boyutların küçük olması nedeniyle alıcı-verici kanal sayısı çok sınırlanmakta ve dolayısıyla yapay evreli dizi teknikleri kullanılmaktadır. Öte yandan, harekete bağlı görüntü bozukluklarını azaltmak için işaret gönderme alma adım sayısının azaltılması gerekmektedir. Bu, eşdeğer dizideki fazlalık frekans bileşenleri azaltılarak sağlanabilir. Bu çalışmada, eşdeğer dizideki fazlalık frekans bileşenlerinin azaltılmasına dayalı farklı örnekleme teknikleri incelenmiştir. Bu tekniklerin görüntü kalitesi 64 elemanlı bir halkasal dizinin asıl ve kontrol eşdeğer dizileri referans alınarak karşılaştırmalı olarak irdelenmiştir. Benzetim sonuçları 64 elemanlı bir halka dizi için 2049 asıl küme, 350 azaltılmış küme 40 dB içinde eşdeğer performans vermektedir.Yayın Forward-looking IVUS imaging using a dual-annular ring CMUT array: Experimental results(IEEE, 2007) Güldiken, Rasim Oytun; Zahorian, Jaime S.; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Tekeş, Coşkun; Hasler, Paul E.; Karaman, Mustafa; Carlier, Stephane; Değertekin, Fahrettin LeventThis paper presents the experimental results on forward-looking Intravascular ultrasound (FL-IVUS) using dual-annular-ring CMUT arrays. The array has a diameter of 1mm including bondpads which consists of separate, concentric 24 transmit and 32 receive ring arrays built on the same silicon substrate. This configuration has the potential for Independent optimization of each array and uses the silicon area more effectively without any drawback. For imaging experiments, we designed and constructed a custom integrated circuit using a standard 0.5 mu m CMOS process for data acquisition. A sample pulse-echo signal received from the oil-air Interface (plane reflector) at 6mm had a center frequency of 11MHz with 95% fractional 6-dB bandwidth. The measured SNR of the echo was 24 dB with no averaging. B-scan image of a wire-phantom was generated to test the resolution.












