Arama Sonuçları

Listeleniyor 1 - 5 / 5
  • Yayın
    Sperm morphology analysis with CNN based algorithms
    (IEEE Computer Society, 2014-08-29) Şavkay, Osman Levent; Cesur, Evren; Yalçın, Müştak Erhan; Tavşanoğlu, Ahmet Vedat
    In this paper Morphological Analysis part of our proposed computer-aided sperm analysis system (CASA) is simulated and the results beside the algorithm steps are presented. The morphology analysis is simply dealing with shape of the sperms and extracting the shape characteristics in medical parameters. The characteristics are obtained by image processing algorithms which utilizes Cellular Nanoscale Network (CNN) based and spatial image processing blocks. The following calculation of medical parameters are obtained from the outputs of image processing blocks. The algorithm is so designed to adapt the final SoC architecture such as Xilinx Zynq7000 device.
  • Yayın
    Etkileşimli öğrenme ile akciğer tomografi hacim taramalarında nodül tespiti
    (Institute of Electrical and Electronics Engineers Inc., 2016-06-20) Çam, İlker; Tek, Faik Boray
    Bu bildiride akciğer BT taramalarında otomatik nodül tespiti yapmak üzere geliştirdigimiz yeni ve özgün bir yöntem sunulmaktadır. Önerdiğimiz yöntem, akciğer organına ve belirli bir nodül tipine bağlı kalmaksızın genelleştirilmiş bir yaklaşım sunmaktadır. Böylelikle akciğer bölütlemesine ihtiyaç duymamaktadır. Düşük doz radyasyonlu ve çeşitli tipte (katı ve kırık cam görünümlü, yüzeye ve damara ilişik) 10 mm’den küçük nodüllerden oluşan zorlu bir tarama kümesinde (Anode09) sınamalar yapılmıştır. Tarama başına ortalama 8 yanlış tespit için nodül tespit duyarlılığı %52’dir. Yarışmada ilk altıya giren algoritmalarla karşılaştırılabilir düzeydedir.
  • Yayın
    Üç boyutlu akustik görüntüleme için ön alıcı-verici tümdevre
    (IEEE, 2004) Çiçek, İhsan; Bozkurt, Ayhan; Karaman, Mustafa
    Tıbbi ultrasonik görüntüleme sistemleri, genel olarak bir çevirici elemanı ve akustik işaretin üretilip algılanmasından sorumlu elektronik oluşmaktadır. Tek boyutlu dönüştürücü dizileriyle, incelenmekte olan ortamın iki boyutlu kesit görüntüsü elde edilmektedir. Dönüştürücü teknolojisindeki son gelişmelerle, iki boyutlu dönüştürücü dizilerinin üretimi gerçekleştirilmiş, böylece üç boyutlu (hacimsel) görüntüleme yapılması mümkün olmuştur[1,2]. Ancak, özellikle Nyquist kriteri, dönüştürücü elemanların boyutlarını sınırladığı için, eleman boyutları oldukça küçülmüştür; bu da algılanan işareti oldukça zayıflatmaktadır. Bu nedenle, kabul edilebilir nitelikteki görüntülerin alınabilmesi için, alıcı-verici elektroniğinin iyileştirilmesi gerekmektedir. Bu çalışmada, iki boyutlu akustik çeviriciler için CMOS tabanlı ön alıcı-verici devresinin tasarımı gerçekleştirilmiştir. Devre, temel olarak, bir yüksek gerilim darbe üretici, alıcı-verici anahtarı, düşük gürültülü ön yükseltici ve dönüştürücü elemanın bağlantı dolgulamasından oluşmaktadır.
  • Yayın
    An integrated circuit with transmit beamforming and parallel receive channels for 3D ultrasound imaging: testing and characterization
    (IEEE, 2007) Wygant, Ira O.; Jamal, Nafis S.; Lee, Hyunjoo J.; Nikoozadeh, Amin; Zhuang, Xuefeng; Oralkan, Ömer; Ergün, Arif Sanlı; Karaman, Mustafa; Khuri-Yakub, Butrus Thomas
    The cost and complexity of medical ultrasound imaging systems can be reduced by integrating the transducer array with an integrated circuit (IC). By incorporating some of the system's front-end electronics into an IC, bulky cables and costly system electronics can be eliminated. Here we present an IC for 3D intracavital imaging that requires few electrical connections but uses a large fraction of a 16x16-element 2D transducer array to transmit focused ultrasound. To simplify the receive and data acquisition electronics, only the 32 elements along the array diagonals are used as receivers. The IC provides a preamplifier for each receiving element. Each of the 224 transmitting elements is provided an 8-bit shift register, a comparator, and a 25-V pulser. To transmit, a global counter is incremented from 1 to 224; each pulser fires when its stored register value is equal to the global count value. Electrical testing of the fabricated IC shows that it works as designed. The IC was flip-chip bonded to a two-dimensional capacitive micromachined ultrasonic transducer (CMUT) array. A two-dimensional image of a wire target phantom was acquired.
  • Yayın
    Çok katmanlı silindirik yapılar için termoakustik dalga denkleminin ters çözümü
    (IEEE, 2017-06-27) Elmas, Demet; Ünalmış Uzun, Banu; İdemen, Mehmet Mithat; Karaman, Mustafa
    Termoakustik görüntüleme, elektromanyetik enerji uyarımı ile ultrason dalgaları oluşumunu sağlayan yeni bir yöntemdir. Bu sistemin görüntüleme işlemi termoakustik dalga denkleminin ters çözümüne dayanmaktadır. Ters çözümde görüntülenecek dokunun homojen yapıda olduğu varsayımı, görüntü kalitesinin azalmasına neden olur. Bu çalışmada, meme ve beyinin görüntülemesinde uygulanabilecek üç boyutlu eş merkezli silindirik çok katmanlı yapılar için termoakustik dalga denkleminin analitik ters çözümü elde edilmiştir. Çözümü sayısal olarak test etmek için, noktasal kaynaklar içeren üç katmanlı fantom kullanılarak numerik simulasyonlar elde edilmiştir.