    Integrated ultrasonic imaging systems based on CMUT arrays: Recent progress
    (IEEE, 2004) Wygant, Ira O.; Zhuang, Xuefeng; Yeh, David T.; Nikoozadeh, Amin; Oralkan, Ömer; Ergün, Arif Sanlı; Karaman, Mustafa; Khuri-Yakub, Butrus Thomas
    This paper describes the development of an ultrasonic imaging system based on a two-dimensional capacitive micromachined ultrasonic transducer (CMUT) array. The transducer array and front-end electronics are designed to fit in a 5-mm endoscopic channel. A custom-designed integrated circuit, which comprises the front-end electronics, will be connected with the transducer elements via through-wafer interconnects and flip-chip bonding. FPGA-based signal-processing hardware will provide real-time three-dimensional imaging. The imaging system is being developed to demonstrate a means of integrating the front-end electronics with the transducer array and to provide a clinically useful technology. Integration of the electronics can improve signal-to-noise ratio, reduce the number of cables connecting the imaging probe to a separate processing unit, and provide a means of connecting electronics to large two-dimensional transducer arrays. This paper describes the imaging system architecture and the progress we have made on implementing each of its components: a 16×16 CMUT array, custom-designed integrated circuits, a flip-chip bonding technique, and signal-processing hardware.
  • Yayın
    Dual-annular-ring CMUT array for forward-looking IVUS imaging
    (IEEE, 2006) Güldiken, Rasim Oytun; Zahorian, Jaime; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Tekeş, Coşkun; Şişman, Alper; Karaman, Mustafa
    We investigate a dual-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. The array consists of separate, concentric transmit and receive ring arrays built on the same silicon substrate. This configuration has the potential for independent optimization of each array and uses the silicon area more effectively without any particular drawback. We designed and fabricated a 1mm diameter test array which consists of 24 transmit and 32 receive elements. We investigated synthetic phased array beamforming with a non-redundant subset (if transmit-receive element pairs of the dual-annular-ring array. For imaging experiments, we designed and constructed a programmable FPGA-based data acquisition and phased array beamforming system. Pulse-echo measurements along with imaging simulations suggest that dual-ring-annular array should provide performance suitable for real-time FLAVUS applications.
  • Yayın
    Damar içi öne bakan ultrasonik görüntüleme için eşdeğer dizi örnekleme yöntemleri
    (IEEE, 2009-06-26) Tekeş, Coşkun; Karaman, Mustafa
    Damar içi öne bakan ultrasonik görüntüleme gerçek zamanlı hacimsel (üç boyutlu) görüntülemeye imkan vermesi bakımından yaygın olarak kullanılmaktadır. Damar içi görüntülemede fiziksel boyutların küçük olması nedeniyle alıcı-verici kanal sayısı çok sınırlanmakta ve dolayısıyla yapay evreli dizi teknikleri kullanılmaktadır. Öte yandan, harekete bağlı görüntü bozukluklarını azaltmak için işaret gönderme alma adım sayısının azaltılması gerekmektedir. Bu, eşdeğer dizideki fazlalık frekans bileşenleri azaltılarak sağlanabilir. Bu çalışmada, eşdeğer dizideki fazlalık frekans bileşenlerinin azaltılmasına dayalı farklı örnekleme teknikleri incelenmiştir. Bu tekniklerin görüntü kalitesi 64 elemanlı bir halkasal dizinin asıl ve kontrol eşdeğer dizileri referans alınarak karşılaştırmalı olarak irdelenmiştir. Benzetim sonuçları 64 elemanlı bir halka dizi için 2049 asıl küme, 350 azaltılmış küme 40 dB içinde eşdeğer performans vermektedir.
  • Yayın
    Forward-looking IVUS imaging using a dual-annular ring CMUT array: Experimental results
    (IEEE, 2007) Güldiken, Rasim Oytun; Zahorian, Jaime S.; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Tekeş, Coşkun; Hasler, Paul E.; Karaman, Mustafa; Carlier, Stephane; Değertekin, Fahrettin Levent
    This paper presents the experimental results on forward-looking Intravascular ultrasound (FL-IVUS) using dual-annular-ring CMUT arrays. The array has a diameter of 1mm including bondpads which consists of separate, concentric 24 transmit and 32 receive ring arrays built on the same silicon substrate. This configuration has the potential for Independent optimization of each array and uses the silicon area more effectively without any drawback. For imaging experiments, we designed and constructed a custom integrated circuit using a standard 0.5 mu m CMOS process for data acquisition. A sample pulse-echo signal received from the oil-air Interface (plane reflector) at 6mm had a center frequency of 11MHz with 95% fractional 6-dB bandwidth. The measured SNR of the echo was 24 dB with no averaging. B-scan image of a wire-phantom was generated to test the resolution.
  • Yayın
    Annular CMUT arrays for side looking intravascular ultrasound imaging
    (IEEE, 2007) Zahorian, Jaime; Güldiken, Rasim Oytun; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Carlier, Stephane; Şişman, Alper; Karaman, Mustafa
    Although side looking intravascular ultrasound (SL-IVUS) imaging systems using single element piezoelectric transducers set the resolution standard in the assessment of the extent of coronary artery disease, improvements in transducer performance are needed to perform harmonic imaging and high resolution imaging of vulnerable plaque. With their small channel count; annular arrays exploiting the inherent broad bandwidth of CMUTs and electronic focusing capability of integrated electronics provide a path for desired SL-IVUS imaging catheters. In this paper, we first describe the design, low temperature fabrication of an 8401 mu m diameter, 8 element CMUT annular array. Testing of the individual elements in oil shows a uniform device behavior with 100% fractional bandwidth around 20MHz without including the effects of attenuation and diffraction. We also present linear scan imaging results obtained on wire targets in oil, tissue and tissue mimicking phantoms using both unfocused and dynamically focused transducers. The results for axial and lateral resolution are in agreement predicted by the simulations and show the feasibility of this approach for high resolution SL-IVUS imaging.
  • Yayın
    Üç boyutlu akustik görüntüleme için ön alıcı-verici tümdevre
    (IEEE, 2004) Çiçek, İhsan; Bozkurt, Ayhan; Karaman, Mustafa
    Tıbbi ultrasonik görüntüleme sistemleri, genel olarak bir çevirici elemanı ve akustik işaretin üretilip algılanmasından sorumlu elektronik oluşmaktadır. Tek boyutlu dönüştürücü dizileriyle, incelenmekte olan ortamın iki boyutlu kesit görüntüsü elde edilmektedir. Dönüştürücü teknolojisindeki son gelişmelerle, iki boyutlu dönüştürücü dizilerinin üretimi gerçekleştirilmiş, böylece üç boyutlu (hacimsel) görüntüleme yapılması mümkün olmuştur[1,2]. Ancak, özellikle Nyquist kriteri, dönüştürücü elemanların boyutlarını sınırladığı için, eleman boyutları oldukça küçülmüştür; bu da algılanan işareti oldukça zayıflatmaktadır. Bu nedenle, kabul edilebilir nitelikteki görüntülerin alınabilmesi için, alıcı-verici elektroniğinin iyileştirilmesi gerekmektedir. Bu çalışmada, iki boyutlu akustik çeviriciler için CMOS tabanlı ön alıcı-verici devresinin tasarımı gerçekleştirilmiştir. Devre, temel olarak, bir yüksek gerilim darbe üretici, alıcı-verici anahtarı, düşük gürültülü ön yükseltici ve dönüştürücü elemanın bağlantı dolgulamasından oluşmaktadır.
  • Yayın
    An integrated circuit with transmit beamforming and parallel receive channels for 3D ultrasound imaging: testing and characterization
    (IEEE, 2007) Wygant, Ira O.; Jamal, Nafis S.; Lee, Hyunjoo J.; Nikoozadeh, Amin; Zhuang, Xuefeng; Oralkan, Ömer; Ergün, Arif Sanlı; Karaman, Mustafa; Khuri-Yakub, Butrus Thomas
    The cost and complexity of medical ultrasound imaging systems can be reduced by integrating the transducer array with an integrated circuit (IC). By incorporating some of the system's front-end electronics into an IC, bulky cables and costly system electronics can be eliminated. Here we present an IC for 3D intracavital imaging that requires few electrical connections but uses a large fraction of a 16x16-element 2D transducer array to transmit focused ultrasound. To simplify the receive and data acquisition electronics, only the 32 elements along the array diagonals are used as receivers. The IC provides a preamplifier for each receiving element. Each of the 224 transmitting elements is provided an 8-bit shift register, a comparator, and a 25-V pulser. To transmit, a global counter is incremented from 1 to 224; each pulser fires when its stored register value is equal to the global count value. Electrical testing of the fabricated IC shows that it works as designed. The IC was flip-chip bonded to a two-dimensional capacitive micromachined ultrasonic transducer (CMUT) array. A two-dimensional image of a wire target phantom was acquired.
  • Yayın
    Çok katmanlı silindirik yapılar için termoakustik dalga denkleminin ters çözümü
    (IEEE, 2017-06-27) Elmas, Demet; Ünalmış Uzun, Banu; İdemen, Mehmet Mithat; Karaman, Mustafa
    Termoakustik görüntüleme, elektromanyetik enerji uyarımı ile ultrason dalgaları oluşumunu sağlayan yeni bir yöntemdir. Bu sistemin görüntüleme işlemi termoakustik dalga denkleminin ters çözümüne dayanmaktadır. Ters çözümde görüntülenecek dokunun homojen yapıda olduğu varsayımı, görüntü kalitesinin azalmasına neden olur. Bu çalışmada, meme ve beyinin görüntülemesinde uygulanabilecek üç boyutlu eş merkezli silindirik çok katmanlı yapılar için termoakustik dalga denkleminin analitik ters çözümü elde edilmiştir. Çözümü sayısal olarak test etmek için, noktasal kaynaklar içeren üç katmanlı fantom kullanılarak numerik simulasyonlar elde edilmiştir.