3 sonuçlar
Arama Sonuçları
Listeleniyor 1 - 3 / 3
Yayın Status of the Focal Plane Instrumentation (FPI) Project of the 4 m DAG Telescope(SPIE, 2016-08-09) Keskin, Onur; Yerli, Sinan Kaan; Yeşilyaprak, Cahit; Güver, Tolga; Aliş, Sinan; Yelkenci, Filiz Korhan; Güçsav, Bülent Burak; Arabacı, Mehtap Özbey; Erol, AyşeDAG (Eastern Anatolia Observatory in Turkish) will be the newest and largest (4m) observatory of Turkey in both optical (VIS) and near-infrared (NIR) Owith its robust observing site infrastructure. The telescope is designedOto house 2 Nasmyth platformes which will be dedicated to NIR and VIS observations. A collaboration has recently been established among four Turkish universities including FMV Isik University (for adaptive optics systems), Middle East Technical University (fort measurement, test and calibration purposes), Istanbul University (for new technology instruments, e.g. MKIDs) and as the coordinator Ataturk University (for obtaining NIR and VIS instruments). In this paper the status of the recently approved FPI project and its aims are presented and possible collaboration opportunities are emphasized.Yayın Improving the calibration time of traffic simulation models using parallel computing technique(Institute of Electrical and Electronics Engineers Inc., 2019-06) Dadashzadeh, Nima; Ergün, Murat; Kesten, Ali Sercan; Zura, MarijanThe calibration procedure for traffic simulation models can be a very time-consuming process in the case of a large-scale and complex network. In the application of Evolutionary Algorithms (EA) such as Genetic Algorithms (GA) and Particle Swarm Optimization (PSO) for calibration of traffic simulation models, objective function evaluation is the most time-consuming step in such calibration problems, because EA has to run a traffic simulation and calculate its corresponding objective function value once for each set of parameters. The main contribution of this study has been to develop a quick calibration procedure for the parameters of driving behavior models using EA and parallel computing techniques (PCTs). The proposed method was coded and implemented in a microscopic traffic simulation software. Two scenarios with/without PCT were analyzed using the developed methodology. The results of scenario analysis show that using an integrated calibration and PCT can reduce the total computational time of the optimization process significantly-in our experiments by 50%-and improve the optimization algorithm's performance in a complex optimization problem. The proposed method is useful for overcoming the limitation of computational time of the existing calibration methods and can be applied to various EAs and traffic simulation software.Yayın Potassium determinations using sem, faas and xrf: some experimental notes(University of Aegean, 2011) Liritzis, Ioannis; Mavrikis, D; Zacharias, Nikolaos; Sakalis, Anastasios; Tsirliganis, Nestor C.; Polymeris, George S.The calibration of Scanning Electron Microscopy coupled with Energy Dispersive X-Rays Spectrometry (SEM-EDS) for elemental quantitative analysis is an important task for characterization, provenance and absolute dating purposes. In particular the potassium determination is an important contributor to dose rate assessments in luminescence and Electron Spin Resonance (ESR) dating. Here a SEM-EDX is calibrated on different archaeological and geoarchaeological materials against standard laboratory samples as well as measured by micro X-Rays Fluorescence (mu XRF) and flame atomic absorption spectroscopy (FAAS) techniques. A common linear relationship is obtained for most elements and certain rock types used and two clear linear regressions for two types of rocks; one for granite, diorite, microgranite and sediments and another ceramic sherds, soils, marble schists, breccia. Such linear regressions become readily available for a future fast, efficient and accurate way of potassium determination.












