Yazar "Değertekin, Fahrettin Levent" için WOS listeleme
-
An Analog beamformer for integrated high-frequency medical ultrasound imaging
Gürün, Gökçe; Zahorian, Jaime; Tekeş, Coşkun; Karaman, Mustafa; Hasler, Paul E.; Değertekin, Fahrettin Levent (IEEE, 2011)We designed and fabricated a dynamic receive beamforming integrated circuit (IC) in 0.35-mu m CMOS technology. This beamformer is suitable for integration with an ultrasound annular array for high-frequency (30-50 MHz) ... -
An analog integrated circuit beamformer for high-frequency medical ultrasound imaging
Gürün, Gökçe; Zahorian, Jaime S.; Şişman, Alper; Karaman, Mustafa; Hasler, Paul E.; Değertekin, Fahrettin Levent (IEEE-INST Electrical Electronics Engineers Inc, 2012-10)We designed and fabricated a dynamic receive beamformer integrated circuit (IC) in 0.35-mu m CMOS technology. This beamformer IC is suitable for integration with an annular array transducer for high-frequency (30-50 MHz) ... -
Annular CMUT arrays for side looking intravascular ultrasound imaging
Zahorian, Jaime; Güldiken, Rasim Oytun; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Carlier, Stephane; Şişman, Alper; Karaman, Mustafa (IEEE, 2007)Although side looking intravascular ultrasound (SL-IVUS) imaging systems using single element piezoelectric transducers set the resolution standard in the assessment of the extent of coronary artery disease, improvements ... -
Annular-ring CMUT arrays for forward-looking IVUS: Transducer characterization and imaging
Değertekin, Fahrettin Levent; Güldiken, Rasim Oytun; Karaman, Mustafa (IEEE, 2006-02)In this study, a 64-element, 1.15-mm diameter annular-ring capacitive micromachined ultrasonic transducer (CMUT) array was characterized and used for forward-looking intravascular ultrasound (IVUS) imaging tests. The array ... -
CMUT-based volumetric ultrasonic imaging array design for forward looking ICE and IVUS applications
Tekeş, Coşkun; Zahorian, Jaime S.; Xu, Toby; Rashid, Muhammad Wasequr; Satır, Sarp; Gürün, Gökçe; Karaman, Mustafa; Hasler, Jennifer Olson; Değertekin, Fahrettin Levent (SPIE-Int Soc Optical Engineering, 2013)Designing a mechanically flexible catheter based volumetric ultrasonic imaging device for intravascular and intracardiac imaging is challenging due to small transducer area and limited number of cables. With a few parallel ... -
Dual electrode capacitive micromachined ultrasonic transducer array for 1-D intracardiac echocardiography (ICE)
Güldiken, Rasim Oytun; Zahorian, Jaime S.; Karaman, Mustafa; Değertekin, Fahrettin Levent (American Society of Mechanical Engineers (ASME), 2007)We designed and fabricated a 64 element 1-D linear dual electrode Capacitive Micromachined Ultrasonic Transducer (CMUT) array operating at 9.5 MHz for Intracardiac Echocardiography (ICE). The dual electrode CMUT structure ... -
Dual-annular-ring CMUT array for forward-looking IVUS imaging
Güldiken, Rasim Oytun; Zahorian, Jaime; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Tekeş, Coşkun; Şişman, Alper; Karaman, Mustafa (IEEE, 2006)We investigate a dual-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. The array consists of separate, concentric transmit and receive ring arrays built on the same ... -
Experimental study of dual-ring CMUT array optimization for forward-looking IVUS
Tekeş, Coşkun; Zahorian, Jaime; Gürün, Gökçe; Satir, Sarp; Hochman, Michael; Xu, Toby; Rashid, Muhammad Wasequr; Değertekin, Fahrettin Levent; Karaman, Mustafa (IEEE, 2011)Forward-looking (FL) catheters have guiding and volumetric imaging capacities which are highly desirable for IVUS applications. Large channel and firing counts have to be reduced to enable 3-D real-time imaging and simplify ... -
Forward-looking IVUS imaging using a dual-annular ring CMUT array: Experimental results
Güldiken, Rasim Oytun; Zahorian, Jaime S.; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Tekeş, Coşkun; Hasler, Paul E.; Karaman, Mustafa; Carlier, Stephane; Değertekin, Fahrettin Levent (IEEE, 2007)This paper presents the experimental results on forward-looking Intravascular ultrasound (FL-IVUS) using dual-annular-ring CMUT arrays. The array has a diameter of 1mm including bondpads which consists of separate, concentric ... -
Forward-looking IVUS imaging using an annular-ring CMUT array
Değertekin, Fahrettin Levent; Karaman, Mustafa; Güldiken, Rasim Oytun (IEEE, 2005)A 64-element, 1.15mm diameter annular-ring CMUT array was characterized and used for forward-looking IVUS imaging tests. The array was manufactured using low temperature processes suitable for CMOS electronics integration ... -
Front-end CMOS electronics for monolithic integration with CMUT arrays: Circuit design and initial experimental results
Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Güldiken, Rasim Oytun; Zahorian, Jaime S.; Peng, Shengyu; Basu, Arindam; Karaman, Mustafa; Hasler, Paul E.; Değertekin, Fahrettin Levent (2008)This paper discusses design of CMOS-ASICs for monolithic integration of CMUT arrays by post-CMOS fabrication. We describe design strategies for monolithic integration and demonstrate the advantages of CMUT-on-CMOS approach. ... -
Micromachined capacitive transducer arrays for intravascular ultrasound
Değertekin, Fahrettin Levent; Güldiken, Rasim Oytun; Karaman, Mustafa (SPIE, 2005)Intravascular ultrasound (IVUS) imaging has become an essential imaging modality for the effective diagnosis and treatment of cardiovascular diseases during the past decade enabled by innovative applications of piezoelectric ... -
Monolithic CMUT-on-CMOS integration for intravascular ultrasound applications
Zahorian, Jaime S.; Hochman, Michael; Xu, Toby; Satır, Sarp; Gürün, Gökçe; Karaman, Mustafa; Değertekin, Fahrettin Levent (IEEE-INST Electrical Electronics Engineers Inc, 2011-12)One of the most important promises of capacitive micromachined ultrasonic transducer (CMUT) technology is integration with electronics. This approach is required to minimize the parasitic capacitances in the receive mode, ... -
Multiple annular ring capacitive micromachined ultrasonic transducer arrays for forward-looking intravascular ultrasound imaging catheters
Güldiken, Rasim Oytun; Zahorian, Jaime S.; Balantekin, Müjdat; Karaman, Mustafa; Değertekin, Fahrettin Levent (American Society of Mechanical Engineers (ASME), 2007)We investigate multiple-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. This configuration has the potential for independent optimization of each ring and uses the ... -
Optimizing circular ring arrays for forward-looking IVUS imaging
Tekeş, Coşkun; Karaman, Mustafa; Değertekin, Fahrettin Levent (IEEE-Inst Electrical Electronics Engineers Inc, 2011-12)Forward-looking (FL) catheter-based imaging systems are highly desirable for guiding interventions in intravascular ultrasound (IVUS) applications. One of the main challenges of array-based FL-IVUS systems is the large ...