Ara
Toplam kayıt 395, listelenen: 371-380
Subarray delta-sigma beamforming for ultrasonic imaging
(IEEE, 2002)
We present a beamforming architecture based on subarray processing with non-uniform oversampling 1-bit delta-sigma (??) modulation. The subarray processing combines conventional phased array and synthetic aperture approaches ...
Blind channel estimation for space-time coding systems with Baum-Welch algorithm
(IEEE, 2002)
In recent years, space-time coding is proposed to provide significant capacity gains over the traditional communication systems in fading wireless channels. In this paper, we consider the problem of blind estimation of the ...
A miniature real-time volumetric ultrasound imaging system
(SPIE-Int Soc Optical Engineering, 2005)
Progress made in the development of a miniature real-time volumetric ultrasound imaging system is presented. This system is targeted for use in a 5-mm endoscopic channel and will provide real-time, 30-mm deep, volumetric ...
Dual electrode capacitive micromachined ultrasonic transducer array for 1-D intracardiac echocardiography (ICE)
(American Society of Mechanical Engineers (ASME), 2007)
We designed and fabricated a 64 element 1-D linear dual electrode Capacitive Micromachined Ultrasonic Transducer (CMUT) array operating at 9.5 MHz for Intracardiac Echocardiography (ICE). The dual electrode CMUT structure ...
Micromachined capacitive transducer arrays for intravascular ultrasound
(SPIE, 2005)
Intravascular ultrasound (IVUS) imaging has become an essential imaging modality for the effective diagnosis and treatment of cardiovascular diseases during the past decade enabled by innovative applications of piezoelectric ...
Forward-looking IVUS imaging using an annular-ring CMUT array
(IEEE, 2005)
A 64-element, 1.15mm diameter annular-ring CMUT array was characterized and used for forward-looking IVUS imaging tests. The array was manufactured using low temperature processes suitable for CMOS electronics integration ...
A lumped circuit model for the radiation impedance of a 2D CMUT array element
(IEEE, 2005)
Elements of a 2D array used for 3D acoustic imaging have dimensions smaller than half of the acoustic wavelength due to the Nyquist criteria for spatial sampling. Therefore, analyses involving circuit models for the array ...
Front-end CMOS electronics for monolithic integration with CMUT arrays: Circuit design and initial experimental results
(2008)
This paper discusses design of CMOS-ASICs for monolithic integration of CMUT arrays by post-CMOS fabrication. We describe design strategies for monolithic integration and demonstrate the advantages of CMUT-on-CMOS approach. ...
Multiple annular ring capacitive micromachined ultrasonic transducer arrays for forward-looking intravascular ultrasound imaging catheters
(American Society of Mechanical Engineers (ASME), 2007)
We investigate multiple-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. This configuration has the potential for independent optimization of each ring and uses the ...
Biclustering expression data based on expanding localized substructures
(Springer-Verlag Berlin Heidelberg, 2009)
Biclustering gene expression data is the problem of extracting submatrices of genes and conditions exhibiting significant correlation across both the rows and the columns of a data matrix of expression values. We provide ...