Ara
Toplam kayıt 13, listelenen: 1-10
An Analog beamformer for integrated high-frequency medical ultrasound imaging
(IEEE, 2011)
We designed and fabricated a dynamic receive beamforming integrated circuit (IC) in 0.35-mu m CMOS technology. This beamformer is suitable for integration with an ultrasound annular array for high-frequency (30-50 MHz) ...
Dual electrode capacitive micromachined ultrasonic transducer array for 1-D intracardiac echocardiography (ICE)
(American Society of Mechanical Engineers (ASME), 2007)
We designed and fabricated a 64 element 1-D linear dual electrode Capacitive Micromachined Ultrasonic Transducer (CMUT) array operating at 9.5 MHz for Intracardiac Echocardiography (ICE). The dual electrode CMUT structure ...
Multiple annular ring capacitive micromachined ultrasonic transducer arrays for forward-looking intravascular ultrasound imaging catheters
(American Society of Mechanical Engineers (ASME), 2007)
We investigate multiple-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. This configuration has the potential for independent optimization of each ring and uses the ...
Annular CMUT arrays for side looking intravascular ultrasound imaging
(IEEE, 2007)
Although side looking intravascular ultrasound (SL-IVUS) imaging systems using single element piezoelectric transducers set the resolution standard in the assessment of the extent of coronary artery disease, improvements ...
Forward-looking IVUS imaging using an annular-ring CMUT array
(IEEE, 2005)
A 64-element, 1.15mm diameter annular-ring CMUT array was characterized and used for forward-looking IVUS imaging tests. The array was manufactured using low temperature processes suitable for CMOS electronics integration ...
Evaluation of CMUT annular arrays for side-looking IVUS
(IEEE, 2009)
Side-looking (SL) IVUS probes are extensively used for management of cardiovascular diseases. Currently SL-IVUS imaging probes use either a single rotating transducer element or solid-state arrays. Probes with single ...
A tunable analog delay element for high-frequency dynamic beamforming
(IEEE, 2009)
Implementing beamforming for high frequency arrays is challenging because of the accurate delay requirements at high frequencies. High frequency digital beamforming is not suitable for catheter based applications as a large ...
Co-array optimization of CMUT arrays for forward-looking IVUS
(IEEE, 2009-09)
The ring annular array structure is a preferred configuration for implementing Forward-Looking IVUS (FLIVUS) catheters as it allows for volumetric imaging as well as use of a guidewire at the center. CMUT technology is ...
Dual-annular-ring CMUT array for forward-looking IVUS imaging
(IEEE, 2006)
We investigate a dual-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. The array consists of separate, concentric transmit and receive ring arrays built on the same ...
Annular-ring CMUT arrays for forward-looking IVUS: Transducer characterization and imaging
(IEEE, 2006-02)
In this study, a 64-element, 1.15-mm diameter annular-ring capacitive micromachined ultrasonic transducer (CMUT) array was characterized and used for forward-looking intravascular ultrasound (IVUS) imaging tests. The array ...