Basit öğe kaydını göster

dc.contributor.authorWygant, Ira O.en_US
dc.contributor.authorJamal, Nafis S.en_US
dc.contributor.authorLee, Hyunjoo J.en_US
dc.contributor.authorNikoozadeh, Aminen_US
dc.contributor.authorZhuang, Xuefengen_US
dc.contributor.authorOralkan, Ömeren_US
dc.contributor.authorErgün, Arif Sanlıen_US
dc.contributor.authorKaraman, Mustafaen_US
dc.contributor.authorKhuri-Yakub, Butrus Thomasen_US
dc.date.accessioned2019-08-31T12:10:23Z
dc.date.accessioned2019-08-05T16:03:06Z
dc.date.available2019-08-31T12:10:23Z
dc.date.available2019-08-05T16:03:06Z
dc.date.issued2007
dc.identifier.citationWygant, I. O., Jamal, N. S., Lee, H. J., Nikoozadeh, A., Zhuang, X., Oralkan, Ö., . . . Khuri-Yakub, B. T. (2007). An integrated circuit with transmit beamforming and parallel receive channels for 3D ultrasound imaging: Testing and characterization. Paper presented at the 25-28. doi:10.1109/ULTSYM.2007.20en_US
dc.identifier.isbn9781424413836
dc.identifier.isbn1424413834
dc.identifier.isbn9781424413843
dc.identifier.issn1051-0117
dc.identifier.urihttps://hdl.handle.net/11729/1809
dc.identifier.urihttps://dx.doi.org/10.1109/ULTSYM.2007.20
dc.descriptionThis work was funded by NIH grant CA99059. National Semiconductor (Santa Clara, Ca) provided valuable circuit design support and fabricated the integrated circuits. Pac Tech USA Inc. (Santa Clara, Ca) provided solder-jetting and electroless Ni/Au bumping services. Work was performed in part at the Stanford Nanofabrication Facility (a member of the National Nanotechnology Infrastructure Network) which is supported by the National Science Foundation under Grant ECS-9731293, its lab members, and the industrial members of the Stanford Center for Integrated Systemsen_US
dc.description.abstractThe cost and complexity of medical ultrasound imaging systems can be reduced by integrating the transducer array with an integrated circuit (IC). By incorporating some of the system's front-end electronics into an IC, bulky cables and costly system electronics can be eliminated. Here we present an IC for 3D intracavital imaging that requires few electrical connections but uses a large fraction of a 16x16-element 2D transducer array to transmit focused ultrasound. To simplify the receive and data acquisition electronics, only the 32 elements along the array diagonals are used as receivers. The IC provides a preamplifier for each receiving element. Each of the 224 transmitting elements is provided an 8-bit shift register, a comparator, and a 25-V pulser. To transmit, a global counter is incremented from 1 to 224; each pulser fires when its stored register value is equal to the global count value. Electrical testing of the fabricated IC shows that it works as designed. The IC was flip-chip bonded to a two-dimensional capacitive micromachined ultrasonic transducer (CMUT) array. A two-dimensional image of a wire target phantom was acquired.en_US
dc.description.sponsorshipUnited States Department of Health & Human Servicesen_US
dc.description.sponsorshipNational Institutes of Health (NIH) - USAen_US
dc.description.sponsorshipNational Science Foundation (NSF)en_US
dc.language.isoengen_US
dc.publisherIEEEen_US
dc.relation.ispartofseriesUltrasonics Symposiumen_US
dc.relation.isversionof10.1109/ULTSYM.2007.20
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subject3D intracavital imagingen_US
dc.subject3d ultrasound imagingen_US
dc.subject8-bit shift registeren_US
dc.subjectAcoustic wavesen_US
dc.subjectArray signal processingen_US
dc.subjectArraysen_US
dc.subjectBeamformingen_US
dc.subjectBiomedical electronicsen_US
dc.subjectBiomedical imagingen_US
dc.subjectBiomedical transducersen_US
dc.subjectBiomedical ultrasonicsen_US
dc.subjectCablesen_US
dc.subjectCapacitive micromachined ultrasonic transduceren_US
dc.subjectCapacitive micromachined ultrasonic transducersen_US
dc.subjectCircuit testingen_US
dc.subjectComparatoren_US
dc.subjectComparators (circuits)en_US
dc.subjectCostsen_US
dc.subjectData acquisition electronicsen_US
dc.subjectElectric connectorsen_US
dc.subjectElectrical connectionsen_US
dc.subjectElectrical testingen_US
dc.subjectElectroacoustic transducersen_US
dc.subjectFlip-chip bonded CMUT arrayen_US
dc.subjectFocused ultrasoundsen_US
dc.subjectGlobal countersen_US
dc.subjectIntegrated circuiten_US
dc.subjectIntegrated circuit testingen_US
dc.subjectIntegrated circuitsen_US
dc.subjectMedical ultrasound imaging systemen_US
dc.subjectMedical imagingen_US
dc.subjectMedical ultrasound imaging systemsen_US
dc.subjectOptoelectronic devicesen_US
dc.subjectParallel receive channelen_US
dc.subjectPhantomsen_US
dc.subjectPreamplifieren_US
dc.subjectPreamplifiersen_US
dc.subjectPre-amplifiersen_US
dc.subjectReceive channelsen_US
dc.subjectReceiving elementsen_US
dc.subjectShift registersen_US
dc.subjectSparse arrayen_US
dc.subjectSystem electronicsen_US
dc.subjectThree dimensionalen_US
dc.subjectTransducer arrayen_US
dc.subjectTransducer arraysen_US
dc.subjectTransducersen_US
dc.subjectTransmit beamformingen_US
dc.subjectTwo dimensionalen_US
dc.subjectUltrasonic imagingen_US
dc.subjectUltrasonic transducer arraysen_US
dc.subjectUltrasonic transducersen_US
dc.subjectUltrasonic imagingen_US
dc.subjectUltrasonicsen_US
dc.subjectVoltage 25 Ven_US
dc.subjectWire target phantomen_US
dc.titleAn integrated circuit with transmit beamforming and parallel receive channels for 3D ultrasound imaging: testing and characterizationen_US
dc.typeconferenceObjecten_US
dc.description.versionPublisher's Versionen_US
dc.relation.journal2007 IEEE Ultrasonics Symposium Proceedings, Vols 1-6en_US
dc.contributor.departmentIşık Üniversitesi, Mühendislik Fakültesi, Elektrik-Elektronik Mühendisliği Bölümüen_US
dc.contributor.departmentIşık University, Faculty of Engineering, Department of Electrical-Electronics Engineeringen_US
dc.identifier.startpage25
dc.identifier.endpage28
dc.peerreviewedYesen_US
dc.publicationstatusPublisheden_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorKaraman, Mustafaen_US
dc.relation.indexWOSen_US
dc.relation.indexScopusen_US
dc.relation.indexConference Proceedings Citation Index – Science (CPCI-S)en_US
dc.description.wosidWOS:000254281800005


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.