Ara
Toplam kayıt 8, listelenen: 1-8
An integrated circuit with transmit beamforming and parallel receive channels for 3D ultrasound imaging: testing and characterization
(IEEE, 2007)
The cost and complexity of medical ultrasound imaging systems can be reduced by integrating the transducer array with an integrated circuit (IC). By incorporating some of the system's front-end electronics into an IC, bulky ...
An integrated circuit with transmit beamforming and parallel receive channels for real-time three-dimensional ultrasound imaging
(IEEE, 2006)
We present the design of an integrated circuit (IC) that will be flip-chip bonded to a 16 x 16-element CMUT array. The IC provides 16 receive channels which can be configured to receive along either of the array diagonals ...
Volumetric imaging using fan-beam scanning with reduced redundancy 2D arrays
(IEEE, 2006)
Phased array processing with a fully populated 2D array produces the best image quality but requires excessive number of active parallel front-end channels. Here we explore four array designs with reduced redundancy in ...
A miniature real-time volumetric ultrasound imaging system
(SPIE-Int Soc Optical Engineering, 2005)
Progress made in the development of a miniature real-time volumetric ultrasound imaging system is presented. This system is targeted for use in a 5-mm endoscopic channel and will provide real-time, 30-mm deep, volumetric ...
Integrated ultrasonic imaging systems based on CMUT arrays: Recent progress
(IEEE, 2004)
This paper describes the development of an ultrasonic imaging system based on a two-dimensional capacitive micromachined ultrasonic transducer (CMUT) array. The transducer array and front-end electronics are designed to ...
Phased subarray imaging for low-cost, wideband coherent array imaging
(IEEE, 2003)
The front-end hardware complexity of conventional full phased array (FPA) imaging is proportional to the number of array elements. Phased subarray (PSA) imaging has been proposed as a method of reducing the hardware ...
Volumetric imaging using 2D capacitive micromachined ultrasonic transducer arrays (CMUTs): Initial results
(IEEE, 2002)
This paper presents the first volumetric images obtained using a 2D CMUT array with through-wafer via interconnects. An 8×16-element portion of a 32×64-element array flip-chip bonded onto a glass fanout chip was used in ...
An endoscopie imaging system based on a two-dimensional CMUT array: real-time imaging results
(IEEE, 2005)
Real-time catheter-based ultrasound imaging tools are needed for diagnosis and image-guided procedures. The continued development of these tools is partially limited by the difficulty of fabricating two-dimensional array ...