Yazar "Karaman, Mustafa" için WOS İndeksli Bildiri Koleksiyonu listeleme
-
An Analog beamformer for integrated high-frequency medical ultrasound imaging
Gürün, Gökçe; Zahorian, Jaime; Tekeş, Coşkun; Karaman, Mustafa; Hasler, Paul E.; Değertekin, Fahrettin Levent (IEEE, 2011)We designed and fabricated a dynamic receive beamforming integrated circuit (IC) in 0.35-mu m CMOS technology. This beamformer is suitable for integration with an ultrasound annular array for high-frequency (30-50 MHz) ... -
Annular CMUT arrays for side looking intravascular ultrasound imaging
Zahorian, Jaime; Güldiken, Rasim Oytun; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Carlier, Stephane; Şişman, Alper; Karaman, Mustafa (IEEE, 2007)Although side looking intravascular ultrasound (SL-IVUS) imaging systems using single element piezoelectric transducers set the resolution standard in the assessment of the extent of coronary artery disease, improvements ... -
Beamforming and hardware design for a multichannel front-end integrated circuit for real-time 3D catheter-based ultrasonic imaging
Wygant, Ira O.; Karaman, Mustafa; Oralkan, Ömer; Khuri-Yakub, Butrus Thomas (SPIE-Int Soc Optical Engineering, 2006)We are working on integrating front-end electronics with the ultrasound transducer array for real-time 3D ultrasound imaging systems. We achieve this integration by flip-chip bonding a two-dimensional transducer array to ... -
CMUT-based volumetric ultrasonic imaging array design for forward looking ICE and IVUS applications
Tekeş, Coşkun; Zahorian, Jaime S.; Xu, Toby; Rashid, Muhammad Wasequr; Satır, Sarp; Gürün, Gökçe; Karaman, Mustafa; Hasler, Jennifer Olson; Değertekin, Fahrettin Levent (SPIE-Int Soc Optical Engineering, 2013)Designing a mechanically flexible catheter based volumetric ultrasonic imaging device for intravascular and intracardiac imaging is challenging due to small transducer area and limited number of cables. With a few parallel ... -
Cross-sectional thermoacoustic imaging using multi-layer cylindrical media
Elmas, Demet; Ünalmış Uzun, Banu; İdemen, Mehmet Mithat; Karaman, Mustafa (IEEE, 2017-11-10)For cross-sectional two-dimensional thermoacustic imaging of breast and brain, we explored solution of the wave equation using layered tissue model consisting of concentric annular layers on a cylindrical cross-section. ... -
Çok katmanlı düzlemsel ortam için termoakustik dalga denkleminin çözümü
Bayıntır, Hazel; Ünalmış Uzun, Banu; İdemen, Mehmet Mithat; Karaman, Mustafa (IEEE, 2017-06-27)Bu çalışmada, farklı akustik parametrelere sahip çok katmanlı düzlemsel ortam için tüm katmanlarda kaynak dağılımı olduğu varsayımı altında termoakustik dalga denkleminin analitik olarak düz ve ters çözümü elde edilmiştir. ... -
Çok katmanlı silindirik yapılar için termoakustik dalga denkleminin ters çözümü
Elmas, Demet; Ünalmış Uzun, Banu; İdemen, Mehmet Mithat; Karaman, Mustafa (IEEE, 2017-06-27)Termoakustik görüntüleme, elektromanyetik enerji uyarımı ile ultrason dalgaları oluşumunu sağlayan yeni bir yöntemdir. Bu sistemin görüntüleme işlemi termoakustik dalga denkleminin ters çözümüne dayanmaktadır. Ters çözümde ... -
Damar içi öne bakan ultrasonik görüntüleme için eşdeğer dizi örnekleme yöntemleri
Tekeş, Coşkun; Karaman, Mustafa (IEEE, 2009-06-26)Damar içi öne bakan ultrasonik görüntüleme gerçek zamanlı hacimsel (üç boyutlu) görüntülemeye imkan vermesi bakımından yaygın olarak kullanılmaktadır. Damar içi görüntülemede fiziksel boyutların küçük olması nedeniyle ... -
Damariçi yanal kesit görüntüleme için farklı prob yapılarının incelenmesi
Şişman, Alper; Karaman, Mustafa (IEEE, 2009-06-26)Bu çalışmada dönen bir şaftın yanal yüzeyine yerleştirilmiş 8 adet içiçe halka elemanlardan oluşan yana bakan görüntüleme için yeni bir kateter yapısı incelenmiştir. Bu Katater mimarisi basit bir dizi önü alıcı verici ... -
Dual electrode capacitive micromachined ultrasonic transducer array for 1-D intracardiac echocardiography (ICE)
Güldiken, Rasim Oytun; Zahorian, Jaime S.; Karaman, Mustafa; Değertekin, Fahrettin Levent (American Society of Mechanical Engineers (ASME), 2007)We designed and fabricated a 64 element 1-D linear dual electrode Capacitive Micromachined Ultrasonic Transducer (CMUT) array operating at 9.5 MHz for Intracardiac Echocardiography (ICE). The dual electrode CMUT structure ... -
Dual-annular-ring CMUT array for forward-looking IVUS imaging
Güldiken, Rasim Oytun; Zahorian, Jaime; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Tekeş, Coşkun; Şişman, Alper; Karaman, Mustafa (IEEE, 2006)We investigate a dual-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. The array consists of separate, concentric transmit and receive ring arrays built on the same ... -
Experimental study of dual-ring CMUT array optimization for forward-looking IVUS
Tekeş, Coşkun; Zahorian, Jaime; Gürün, Gökçe; Satir, Sarp; Hochman, Michael; Xu, Toby; Rashid, Muhammad Wasequr; Değertekin, Fahrettin Levent; Karaman, Mustafa (IEEE, 2011)Forward-looking (FL) catheters have guiding and volumetric imaging capacities which are highly desirable for IVUS applications. Large channel and firing counts have to be reduced to enable 3-D real-time imaging and simplify ... -
Forward-looking IVUS imaging using a dual-annular ring CMUT array: Experimental results
Güldiken, Rasim Oytun; Zahorian, Jaime S.; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Tekeş, Coşkun; Hasler, Paul E.; Karaman, Mustafa; Carlier, Stephane; Değertekin, Fahrettin Levent (IEEE, 2007)This paper presents the experimental results on forward-looking Intravascular ultrasound (FL-IVUS) using dual-annular-ring CMUT arrays. The array has a diameter of 1mm including bondpads which consists of separate, concentric ... -
Forward-looking IVUS imaging using an annular-ring CMUT array
Değertekin, Fahrettin Levent; Karaman, Mustafa; Güldiken, Rasim Oytun (IEEE, 2005)A 64-element, 1.15mm diameter annular-ring CMUT array was characterized and used for forward-looking IVUS imaging tests. The array was manufactured using low temperature processes suitable for CMOS electronics integration ... -
Front-end CMOS electronics for monolithic integration with CMUT arrays: Circuit design and initial experimental results
Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Güldiken, Rasim Oytun; Zahorian, Jaime S.; Peng, Shengyu; Basu, Arindam; Karaman, Mustafa; Hasler, Paul E.; Değertekin, Fahrettin Levent (2008)This paper discusses design of CMOS-ASICs for monolithic integration of CMUT arrays by post-CMOS fabrication. We describe design strategies for monolithic integration and demonstrate the advantages of CMUT-on-CMOS approach. ... -
An integrated circuit with transmit beamforming and parallel receive channels for 3D ultrasound imaging: testing and characterization
Wygant, Ira O.; Jamal, Nafis S.; Lee, Hyunjoo J.; Nikoozadeh, Amin; Zhuang, Xuefeng; Oralkan, Ömer; Ergün, Arif Sanlı; Karaman, Mustafa; Khuri-Yakub, Butrus Thomas (IEEE, 2007)The cost and complexity of medical ultrasound imaging systems can be reduced by integrating the transducer array with an integrated circuit (IC). By incorporating some of the system's front-end electronics into an IC, bulky ... -
An integrated circuit with transmit beamforming and parallel receive channels for real-time three-dimensional ultrasound imaging
Wygant, Ira O.; Lee, Hyunjoo J.; Nikoozadeh, Amin; Yeh, David T.; Oralkan, Ömer; Karaman, Mustafa; Khuri-Yakub, Butrus Thomas (IEEE, 2006)We present the design of an integrated circuit (IC) that will be flip-chip bonded to a 16 x 16-element CMUT array. The IC provides 16 receive channels which can be configured to receive along either of the array diagonals ... -
Integrated ultrasonic imaging systems based on CMUT arrays: Recent progress
Wygant, Ira O.; Zhuang, Xuefeng; Yeh, David T.; Nikoozadeh, Amin; Oralkan, Ömer; Ergün, Arif Sanlı; Karaman, Mustafa; Khuri-Yakub, Butrus Thomas (IEEE, 2004)This paper describes the development of an ultrasonic imaging system based on a two-dimensional capacitive micromachined ultrasonic transducer (CMUT) array. The transducer array and front-end electronics are designed to ... -
A lumped circuit model for the radiation impedance of a 2D CMUT array element
Bozkurt, Ayhan; Karaman, Mustafa (IEEE, 2005)Elements of a 2D array used for 3D acoustic imaging have dimensions smaller than half of the acoustic wavelength due to the Nyquist criteria for spatial sampling. Therefore, analyses involving circuit models for the array ... -
Micromachined capacitive transducer arrays for intravascular ultrasound
Değertekin, Fahrettin Levent; Güldiken, Rasim Oytun; Karaman, Mustafa (SPIE, 2005)Intravascular ultrasound (IVUS) imaging has become an essential imaging modality for the effective diagnosis and treatment of cardiovascular diseases during the past decade enabled by innovative applications of piezoelectric ...